serverTech Sentry4-MIB Object-Id Tree -- created from sentry4 (202104121535Z) = st4UnitIndex, 1 to 6 per system = st4InputCordIndex, 1 to 4 per unit = st4LineIndex, 1 to 4 per cord = st4PhaseIndex, 1 to 6 per cord = st4OcpIndex, 1 to 64 per cord = st4BranchIndex, 1 to 64 per cord = st4OutletIndex, 1 to 128 per cord = st4TempSensorIndex, 1 to 2 per unit = st4HumidSensorIndex, 1 to 2 per unit = st4WaterSensorIndex, 1 per unit = st4CcSensorIndex, 1 to 4 per unit = st4AdcSensorIndex, 1 per unit = st4FanSensorIndex, 1 to 4 per unit r- = read-only rw = read-write -- = not accessible serverTech(enterprises 1718) .1.3.6.1.4.1.1718 | | +--sentry4(1.3.6.1.4.1.1718.4) +- .4 | | +--st4Objects(1) +- .1 | | | | | +--st4System(1) | +- .1 | | | | | | | | +--st4SystemConfig(1) | | +- .1 | | | | | | | | +-- r- st4SystemProductName(1) | | +- .1 .0 | | +-- rw st4SystemLocation(2) | | +- .2 .0 | | +-- r- st4SystemFirmwareVersion(3) | | +- .3 .0 | | +-- r- st4SystemFirmwareBuildInfo(4) | | +- .4 .0 | | +-- r- st4SystemNICSerialNumber(5) | | +- .5 .0 | | +-- r- st4SystemNICHardwareInfo(6) | | +- .6 .0 | | +-- r- st4SystemProductSeries(7) | | +- .7 .0 | | +-- r- st4SystemFeatures(10) | | +- .10 .0 | | +-- rw st4SystemFeatureKey(11) | | +- .11 .0 | | +-- r- st4SystemConfigModifiedCount(20) | | +- .20 .0 | | +-- r- st4SystemUnitCount(21) | | +- .21 .0 | | | | | +--st4Units(2) | +- .2 | | | | | | | | +--st4UnitCommonConfig(1) | | +- .1 | | | | | | | | +--st4UnitConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4UnitConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4UnitIndex(1) | | | +- .1 | | | +-- r- st4UnitID(2) | | | +- .2 . | | | +-- rw st4UnitName(3) | | | +- .3 . | | | +-- r- st4UnitProductSN(4) | | | +- .4 . | | | +-- r- st4UnitModel(5) | | | +- .5 . | | | +-- rw st4UnitAssetTag(6) | | | +- .6 . | | | +-- r- st4UnitType(7) | | | +- .7 . | | | +-- r- st4UnitCapabilities(8) | | | +- .8 . | | | +-- r- st4UnitProductMfrDate(9) | | | +- .9 . | | | +-- rw st4UnitDisplayOrientation(20) | | | +- .20 . | | | +-- rw st4UnitOutletSequenceOrder(21) | | | +- .21 . | | | +-- rw st4UnitOutletDisplayOrder(22) | | | +- .22 . | | | +-- r- st4UnitInputCordCount(30) | | | +- .30 . | | | +-- r- st4UnitTempSensorCount(31) | | | +- .31 . | | | +-- r- st4UnitHumidSensorCount(32) | | | +- .32 . | | | +-- r- st4UnitWaterSensorCount(33) | | | +- .33 . | | | +-- r- st4UnitCcSensorCount(34) | | | +- .34 . | | | +-- r- st4UnitAdcSensorCount(35) | | | +- .35 . | | | +-- r- st4UnitFanSensorCount(36) | | | +- .36 . | | | | | | | | +--st4UnitMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4UnitMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4UnitStatus(1) | | | +- .1 . | | | | | | | | +--st4UnitEventConfigTable(4) | | +- .4 | | | | | | | | +--st4UnitEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4UnitNotifications(1) | | +- .1 . | | | | | +--st4InputCords(3) | +- .3 | | | | | | | | +--st4InputCordCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4InputCordActivePowerHysteresis(1) | | | +- .1 .0 | | | +-- rw st4InputCordApparentPowerHysteresis(2) | | | +- .2 .0 | | | +-- rw st4InputCordPowerFactorHysteresis(3) | | | +- .3 .0 | | | +-- rw st4InputCordOutOfBalanceHysteresis(4) | | | +- .4 .0 | | | | | | | | +--st4InputCordConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4InputCordConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4InputCordIndex(1) | | | +- .1 | | | +-- r- st4InputCordID(2) | | | +- .2 . . | | | +-- rw st4InputCordName(3) | | | +- .3 . . | | | +-- r- st4InputCordInletType(6) | | | +- .6 . . | | | +-- rw st4InputCordNominalVoltage(7) | | | +- .7 . . | | | +-- r- st4InputCordNominalVoltageMin(8) | | | +- .8 . . | | | +-- r- st4InputCordNominalVoltageMax(9) | | | +- .9 . . | | | +-- rw st4InputCordCurrentCapacity(10) | | | +- .10 . . | | | +-- r- st4InputCordCurrentCapacityMax(11) | | | +- .11 . . | | | +-- r- st4InputCordPowerCapacity(12) | | | +- .12 . . | | | +-- rw st4InputCordNominalPowerFactor(13) | | | +- .13 . . | | | +-- r- st4InputCordLineCount(20) | | | +- .20 . . | | | +-- r- st4InputCordPhaseCount(21) | | | +- .21 . . | | | +-- r- st4InputCordOcpCount(22) | | | +- .22 . . | | | +-- r- st4InputCordBranchCount(23) | | | +- .23 . . | | | +-- r- st4InputCordOutletCount(24) | | | +- .24 . . | | | | | | | | +--st4InputCordMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4InputCordMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4InputCordState(1) | | | +- .1 . . | | | +-- r- st4InputCordStatus(2) | | | +- .2 . . | | | +-- r- st4InputCordActivePower(3) | | | +- .3 . . | | | +-- r- st4InputCordActivePowerStatus(4) | | | +- .4 . . | | | +-- r- st4InputCordApparentPower(5) | | | +- .5 . . | | | +-- r- st4InputCordApparentPowerStatus(6) | | | +- .6 . . | | | +-- r- st4InputCordPowerUtilized(7) | | | +- .7 . . | | | +-- r- st4InputCordPowerFactor(8) | | | +- .8 . . | | | +-- r- st4InputCordPowerFactorStatus(9) | | | +- .9 . . | | | +-- r- st4InputCordEnergy(10) | | | +- .10 . . | | | +-- r- st4InputCordFrequency(11) | | | +- .11 . . | | | +-- r- st4InputCordOutOfBalance(12) | | | +- .12 . . | | | +-- r- st4InputCordOutOfBalanceStatus(13) | | | +- .13 . . | | | | | | | | +--st4InputCordEventConfigTable(4) | | +- .4 | | | | | | | | +--st4InputCordEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4InputCordNotifications(1) | | +- .1 . . | | +-- rw st4InputCordActivePowerLowAlarm(2) | | +- .2 . . | | +-- rw st4InputCordActivePowerLowWarning(3) | | +- .3 . . | | +-- rw st4InputCordActivePowerHighWarning(4) | | +- .4 . . | | +-- rw st4InputCordActivePowerHighAlarm(5) | | +- .5 . . | | +-- rw st4InputCordApparentPowerLowAlarm(6) | | +- .6 . . | | +-- rw st4InputCordApparentPowerLowWarning(7) | | +- .7 . . | | +-- rw st4InputCordApparentPowerHighWarning(8) | | +- .8 . . | | +-- rw st4InputCordApparentPowerHighAlarm(9) | | +- .9 . . | | +-- rw st4InputCordPowerFactorLowAlarm(10) | | +- .10 . . | | +-- rw st4InputCordPowerFactorLowWarning(11) | | +- .11 . . | | +-- rw st4InputCordOutOfBalanceHighWarning(12) | | +- .12 . . | | +-- rw st4InputCordOutOfBalanceHighAlarm(13) | | +- .13 . . | | | | | +--st4Lines(4) | +- .4 | | | | | | | | +--st4LineCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4LineCurrentHysteresis(1) | | | +- .1 .0 | | | | | | | | +--st4LineConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4LineConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4LineIndex(1) | | | +- .1 | | | +-- r- st4LineID(2) | | | +- .2 . . . | | | +-- r- st4LineLabel(4) | | | +- .4 . . . | | | +-- r- st4LineCurrentCapacity(6) | | | +- .6 . . . | | | | | | | | +--st4LineMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4LineMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4LineState(1) | | | +- .1 . . . | | | +-- r- st4LineStatus(2) | | | +- .2 . . . | | | +-- r- st4LineCurrent(3) | | | +- .3 . . . | | | +-- r- st4LineCurrentStatus(4) | | | +- .4 . . . | | | +-- r- st4LineCurrentUtilized(5) | | | +- .5 . . . | | | | | | | | +--st4LineEventConfigTable(4) | | +- .4 | | | | | | | | +--st4LineEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4LineNotifications(1) | | +- .1 . . . | | +-- rw st4LineCurrentLowAlarm(2) | | +- .2 . . . | | +-- rw st4LineCurrentLowWarning(3) | | +- .3 . . . | | +-- rw st4LineCurrentHighWarning(4) | | +- .4 . . . | | +-- rw st4LineCurrentHighAlarm(5) | | +- .5 . . . | | | | | +--st4Phases(5) | +- .5 | | | | | | | | +--st4PhaseCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4PhaseVoltageHysteresis(1) | | | +- .1 .0 | | | +-- rw st4PhasePowerFactorHysteresis(2) | | | +- .2 .0 | | | | | | | | +--st4PhaseConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4PhaseConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4PhaseIndex(1) | | | +- .1 | | | +-- r- st4PhaseID(2) | | | +- .2 . . . | | | +-- r- st4PhaseLabel(4) | | | +- .4 . . . | | | +-- r- st4PhaseNominalVoltage(6) | | | +- .6 . . . | | | +-- r- st4PhaseBranchCount(20) | | | +- .20 . . . | | | +-- r- st4PhaseOutletCount(21) | | | +- .21 . . . | | | | | | | | +--st4PhaseMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4PhaseMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4PhaseState(1) | | | +- .1 . . . | | | +-- r- st4PhaseStatus(2) | | | +- .2 . . . | | | +-- r- st4PhaseVoltage(3) | | | +- .3 . . . | | | +-- r- st4PhaseVoltageStatus(4) | | | +- .4 . . . | | | +-- r- st4PhaseVoltageDeviation(5) | | | +- .5 . . . | | | +-- r- st4PhaseCurrent(6) | | | +- .6 . . . | | | +-- r- st4PhaseCurrentCrestFactor(7) | | | +- .7 . . . | | | +-- r- st4PhaseActivePower(8) | | | +- .8 . . . | | | +-- r- st4PhaseApparentPower(9) | | | +- .9 . . . | | | +-- r- st4PhasePowerFactor(10) | | | +- .10 . . . | | | +-- r- st4PhasePowerFactorStatus(11) | | | +- .11 . . . | | | +-- r- st4PhaseReactance(12) | | | +- .12 . . . | | | +-- r- st4PhaseEnergy(13) | | | +- .13 . . . | | | | | | | | +--st4PhaseEventConfigTable(4) | | +- .4 | | | | | | | | +--st4PhaseEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4PhaseNotifications(1) | | +- .1 . . . | | +-- rw st4PhaseVoltageLowAlarm(2) | | +- .2 . . . | | +-- rw st4PhaseVoltageLowWarning(3) | | +- .3 . . . | | +-- rw st4PhaseVoltageHighWarning(4) | | +- .4 . . . | | +-- rw st4PhaseVoltageHighAlarm(5) | | +- .5 . . . | | +-- rw st4PhasePowerFactorLowAlarm(6) | | +- .6 . . . | | +-- rw st4PhasePowerFactorLowWarning(7) | | +- .7 . . . | | | | | +--st4OverCurrentProtectors(6) | +- .6 | | | | | | | | +--st4OcpCommonConfig(1) | | +- .1 | | | | | | | | +--st4OcpConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4OcpConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4OcpIndex(1) | | | +- .1 | | | +-- r- st4OcpID(2) | | | +- .2 . . . | | | +-- r- st4OcpLabel(4) | | | +- .4 . . . | | | +-- r- st4OcpType(6) | | | +- .6 . . . | | | +-- rw st4OcpCurrentCapacity(7) | | | +- .7 . . . | | | +-- r- st4OcpCurrentCapacityMax(8) | | | +- .8 . . . | | | +-- r- st4OcpBranchCount(20) | | | +- .20 . . . | | | +-- r- st4OcpOutletCount(21) | | | +- .21 . . . | | | | | | | | +--st4OcpMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4OcpMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4OcpStatus(1) | | | +- .1 . . . | | | | | | | | +--st4OcpEventConfigTable(4) | | +- .4 | | | | | | | | +--st4OcpEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4OcpNotifications(1) | | +- .1 . . . | | | | | +--st4Branches(7) | +- .7 | | | | | | | | +--st4BranchCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4BranchCurrentHysteresis(1) | | | +- .1 .0 | | | | | | | | +--st4BranchConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4BranchConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4BranchIndex(1) | | | +- .1 | | | +-- r- st4BranchID(2) | | | +- .2 . . . | | | +-- r- st4BranchLabel(4) | | | +- .4 . . . | | | +-- r- st4BranchCurrentCapacity(6) | | | +- .6 . . . | | | +-- r- st4BranchPhaseID(20) | | | +- .20 . . . | | | +-- r- st4BranchOcpID(21) | | | +- .21 . . . | | | +-- r- st4BranchOutletCount(30) | | | +- .30 . . . | | | | | | | | +--st4BranchMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4BranchMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4BranchState(1) | | | +- .1 . . . | | | +-- r- st4BranchStatus(2) | | | +- .2 . . . | | | +-- r- st4BranchCurrent(3) | | | +- .3 . . . | | | +-- r- st4BranchCurrentStatus(4) | | | +- .4 . . . | | | +-- r- st4BranchCurrentUtilized(5) | | | +- .5 . . . | | | | | | | | +--st4BranchEventConfigTable(4) | | +- .4 | | | | | | | | +--st4BranchEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4BranchNotifications(1) | | +- .1 . . . | | +-- rw st4BranchCurrentLowAlarm(2) | | +- .2 . . . | | +-- rw st4BranchCurrentLowWarning(3) | | +- .3 . . . | | +-- rw st4BranchCurrentHighWarning(4) | | +- .4 . . . | | +-- rw st4BranchCurrentHighAlarm(5) | | +- .5 . . . | | | | | +--st4Outlets(8) | +- .8 | | | | | | | | +--st4OutletCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4OutletCurrentHysteresis(1) | | | +- .1 .0 | | | +-- rw st4OutletActivePowerHysteresis(2) | | | +- .2 .0 | | | +-- rw st4OutletPowerFactorHysteresis(3) | | | +- .3 .0 | | | +-- rw st4OutletSequenceInterval(10) | | | +- .10 .0 | | | +-- rw st4OutletRebootDelay(11) | | | +- .11 .0 | | | +-- rw st4OutletStateChangeLogging(12) | | | +- .12 .0 | | | | | | | | +--st4OutletConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4OutletConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4OutletIndex(1) | | | +- .1 | | | +-- r- st4OutletID(2) | | | +- .2 . . . | | | +-- rw st4OutletName(3) | | | +- .3 . . . | | | +-- r- st4OutletCapabilities(5) | | | +- .5 . . . | | | +-- r- st4OutletSocketType(6) | | | +- .6 . . . | | | +-- r- st4OutletCurrentCapacity(7) | | | +- .7 . . . | | | +-- r- st4OutletPowerCapacity(8) | | | +- .8 . . . | | | +-- rw st4OutletSocketAdapter(9) | | | +- .9 . . . | | | +-- rw st4OutletWakeupState(20) | | | +- .20 . . . | | | +-- rw st4OutletPostOnDelay(21) | | | +- .21 . . . | | | +-- r- st4OutletPhaseID(30) | | | +- .30 . . . | | | +-- r- st4OutletOcpID(31) | | | +- .31 . . . | | | +-- r- st4OutletBranchID(32) | | | +- .32 . . . | | | | | | | | +--st4OutletMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4OutletMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4OutletState(1) | | | +- .1 . . . | | | +-- r- st4OutletStatus(2) | | | +- .2 . . . | | | +-- r- st4OutletCurrent(3) | | | +- .3 . . . | | | +-- r- st4OutletCurrentStatus(4) | | | +- .4 . . . | | | +-- r- st4OutletCurrentUtilized(5) | | | +- .5 . . . | | | +-- r- st4OutletVoltage(6) | | | +- .6 . . . | | | +-- r- st4OutletActivePower(7) | | | +- .7 . . . | | | +-- r- st4OutletActivePowerStatus(8) | | | +- .8 . . . | | | +-- r- st4OutletApparentPower(9) | | | +- .9 . . . | | | +-- r- st4OutletPowerFactor(10) | | | +- .10 . . . | | | +-- r- st4OutletPowerFactorStatus(11) | | | +- .11 . . . | | | +-- r- st4OutletCurrentCrestFactor(12) | | | +- .12 . . . | | | +-- r- st4OutletReactance(13) | | | +- .13 . . . | | | +-- r- st4OutletEnergy(14) | | | +- .14 . . . | | | | | | | | +--st4OutletEventConfigTable(4) | | +- .4 | | | | | | | | | | | +--st4OutletEventConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- rw st4OutletNotifications(1) | | | +- .1 . . . | | | +-- rw st4OutletCurrentLowAlarm(2) | | | +- .2 . . . | | | +-- rw st4OutletCurrentLowWarning(3) | | | +- .3 . . . | | | +-- rw st4OutletCurrentHighWarning(4) | | | +- .4 . . . | | | +-- rw st4OutletCurrentHighAlarm(5) | | | +- .5 . . . | | | +-- rw st4OutletActivePowerLowAlarm(6) | | | +- .6 . . . | | | +-- rw st4OutletActivePowerLowWarning(7) | | | +- .7 . . . | | | +-- rw st4OutletActivePowerHighWarning(8) | | | +- .8 . . . | | | +-- rw st4OutletActivePowerHighAlarm(9) | | | +- .9 . . . | | | +-- rw st4OutletPowerFactorLowAlarm(10) | | | +- .10 . . . | | | +-- rw st4OutletPowerFactorLowWarning(11) | | | +- .11 . . . | | | | | | | | +--st4OutletControlTable(5) | | +- .5 | | | | | | | | | | | +--st4OutletControlEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4OutletControlState(1) | | | +- .1 . . . | | | +-- rw st4OutletControlAction(2) | | | +- .2 . . . | | | | | | | | +--st4OutletCommonControl(6) | | +- .6 | | | | | | | | +-- rw st4OutletQueueControl(1) | | +- .1 .0 | | | | | +--st4TemperatureSensors(9) | +- .9 | | | | | | | | +--st4TempSensorCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4TempSensorHysteresis(1) | | | +- .1 .0 | | | +-- rw st4TempSensorScale(10) | | | +- .10 .0 | | | | | | | | +--st4TempSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4TempSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4TempSensorIndex(1) | | | +- .1 | | | +-- r- st4TempSensorID(2) | | | +- .2 . . | | | +-- rw st4TempSensorName(3) | | | +- .3 . . | | | +-- r- st4TempSensorValueMin(4) | | | +- .4 . . | | | +-- r- st4TempSensorValueMax(5) | | | +- .5 . . | | | | | | | | +--st4TempSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4TempSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4TempSensorValue(1) | | | +- .1 . . | | | +-- r- st4TempSensorStatus(2) | | | +- .2 . . | | | | | | | | +--st4TempSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4TempSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4TempSensorNotifications(1) | | +- .1 . . | | +-- rw st4TempSensorLowAlarm(2) | | +- .2 . . | | +-- rw st4TempSensorLowWarning(3) | | +- .3 . . | | +-- rw st4TempSensorHighWarning(4) | | +- .4 . . | | +-- rw st4TempSensorHighAlarm(5) | | +- .5 . . | | | | | +--st4HumiditySensors(10) | +- .10 | | | | | | | | +--st4HumidSensorCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4HumidSensorHysteresis(1) | | | +- .1 .0 | | | | | | | | +--st4HumidSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4HumidSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4HumidSensorIndex(1) | | | +- .1 | | | +-- r- st4HumidSensorID(2) | | | +- .2 . . | | | +-- rw st4HumidSensorName(3) | | | +- .3 . . | | | | | | | | +--st4HumidSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4HumidSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4HumidSensorValue(1) | | | +- .1 . . | | | +-- r- st4HumidSensorStatus(2) | | | +- .2 . . | | | | | | | | +--st4HumidSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4HumidSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4HumidSensorNotifications(1) | | +- .1 . . | | +-- rw st4HumidSensorLowAlarm(2) | | +- .2 . . | | +-- rw st4HumidSensorLowWarning(3) | | +- .3 . . | | +-- rw st4HumidSensorHighWarning(4) | | +- .4 . . | | +-- rw st4HumidSensorHighAlarm(5) | | +- .5 . . | | | | | +--st4WaterSensors(11) | +- .11 | | | | | | | | +--st4WaterSensorCommonConfig(1) | | +- .1 | | | | | | | | +--st4WaterSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4WaterSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4WaterSensorIndex(1) | | | +- .1 | | | +-- r- st4WaterSensorID(2) | | | +- .2 . . | | | +-- rw st4WaterSensorName(3) | | | +- .3 . . | | | | | | | | +--st4WaterSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4WaterSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4WaterSensorStatus(1) | | | +- .1 . . | | | | | | | | +--st4WaterSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4WaterSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4WaterSensorNotifications(1) | | +- .1 . . | | | | | +--st4ContactClosureSensors(12) | +- .12 | | | | | | | | +--st4CcSensorCommonConfig(1) | | +- .1 | | | | | | | | +--st4CcSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4CcSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4CcSensorIndex(1) | | | +- .1 | | | +-- r- st4CcSensorID(2) | | | +- .2 . . | | | +-- rw st4CcSensorName(3) | | | +- .3 . . | | | | | | | | +--st4CcSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4CcSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4CcSensorStatus(1) | | | +- .1 . . | | | | | | | | +--st4CcSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4CcSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4CcSensorNotifications(1) | | +- .1 . . | | | | | +--st4AnalogToDigitalConvSensors(13) | +- .13 | | | | | | | | +--st4AdcSensorCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4AdcSensorHysteresis(1) | | | +- .1 .0 | | | | | | | | +--st4AdcSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4AdcSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4AdcSensorIndex(1) | | | +- .1 | | | +-- r- st4AdcSensorID(2) | | | +- .2 . . | | | +-- rw st4AdcSensorName(3) | | | +- .3 . . | | | | | | | | +--st4AdcSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4AdcSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4AdcSensorValue(1) | | | +- .1 . . | | | +-- r- st4AdcSensorStatus(2) | | | +- .2 . . | | | | | | | | +--st4AdcSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4AdcSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4AdcSensorNotifications(1) | | +- .1 . . | | +-- rw st4AdcSensorLowAlarm(2) | | +- .2 . . | | +-- rw st4AdcSensorLowWarning(3) | | +- .3 . . | | +-- rw st4AdcSensorHighWarning(4) | | +- .4 . . | | +-- rw st4AdcSensorHighAlarm(5) | | +- .5 . . | | | | | +--st4FanSensors(14) | +- .14 | | | | | | | | +--st4FanSensorCommonConfig(1) | | +- .1 | | | | | | | | | | | +-- rw st4FanSensorHysteresis(1) | | | +- .1 .0 | | | | | | | | +--st4FanSensorConfigTable(2) | | +- .2 | | | | | | | | | | | +--st4FanSensorConfigEntry(1) | | | +- .1 | | | | | | | | | | | +-- -- st4FanSensorIndex(1) | | | +- .1 | | | +-- r- st4FanSensorID(2) | | | +- .2 . . | | | +-- rw st4FanSensorName(3) | | | +- .3 . . | | | | | | | | +--st4FanSensorMonitorTable(3) | | +- .3 | | | | | | | | | | | +--st4FanSensorMonitorEntry(1) | | | +- .1 | | | | | | | | | | | +-- r- st4FanSensorValue(1) | | | +- .1 . . | | | +-- r- st4FanSensorStatus(2) | | | +- .2 . . | | | | | | | | +--st4FanSensorEventConfigTable(4) | | +- .4 | | | | | | | | +--st4FanSensorEventConfigEntry(1) | | +- .1 | | | | | | | | +-- rw st4FanSensorNotifications(1) | | +- .1 . . | | +-- rw st4FanSensorLowAlarm(2) | | +- .2 . . | | +-- rw st4FanSensorLowWarning(3) | | +- .3 . . | | +-- rw st4FanSensorHighWarning(4) | | +- .4 . . | | +-- rw st4FanSensorHighAlarm(5) | | +- .5 . . | | | | | +--st4EventInformation(99) | +- .99 | | | | | +-- r- st4EventStatusText(1) | +- .1 .0 | +-- r- st4EventStatusCondition(2) | +- .2 .0 | | +--st4Notifications(100) +- .100 | | | | | +--st4Events(0) | +- .0 | | | | | +--st4UnitStatusEvent(1) | + .1 | +--st4InputCordStatusEvent(2) | + .2 | +--st4InputCordActivePowerEvent(3) | + .3 | +--st4InputCordApparentPowerEvent(4) | + .4 | +--st4InputCordPowerFactorEvent(5) | + .5 | +--st4InputCordOutOfBalanceEvent(6) | + .6 | +--st4LineStatusEvent(7) | + .7 | +--st4LineCurrentEvent(8) | + .8 | +--st4PhaseStatusEvent(9) | + .9 | +--st4PhaseVoltageEvent(10) | + .10 | +--st4PhasePowerFactorEvent(11) | + .11 | +--st4OcpStatusEvent(12) | + .12 | +--st4BranchStatusEvent(13) | + .13 | +--st4BranchCurrentEvent(14) | + .14 | +--st4OutletStatusEvent(15) | + .15 | +--st4OutletChangeEvent(16) | + .16 | +--st4OutletCurrentEvent(17) | + .17 | +--st4OutletActivePowerEvent(18) | + .18 | +--st4OutletPowerFactorEvent(19) | + .19 | +--st4TempSensorEvent(20) | + .20 | +--st4HumidSensorEvent(21) | + .21 | +--st4WaterSensorStatusEvent(22) | + .22 | +--st4CcSensorStatusEvent(23) | + .23 | +--st4AdcSensorEvent(24) | + .24 | +--st4FanSensorEvent(25) | + .25 | | +--st4Conformance(200) +- .200 | | +--st4Groups(1) +- .1 | | | | | +--st4SystemObjectsGroup(1) | +- .1 | +--st4UnitObjectsGroup(2) | +- .2 | +--st4InputCordObjectsGroup(3) | +- .3 | +--st4LineObjectsGroup(4) | +- .4 | +--st4PhaseObjectsGroup(5) | +- .5 | +--st4OcpObjectsGroup(6) | +- .6 | +--st4BranchObjectsGroup(7) | +- .7 | +--st4OutletObjectsGroup(8) | +- .8 | +--st4TempSensorObjectsGroup(9) | +- .9 | +--st4HumidSensorObjectsGroup(10) | +- .10 | +--st4WaterSensorObjectsGroup(11) | +- .11 | +--st4CcSensorObjectsGroup(12) | +- .12 | +--st4AdcSensorObjectsGroup(13) | +- .13 | +--st4FanSensorObjectsGroup(14) | +- .14 | +--st4EventInfoObjectsGroup(99) | +- .99 | +--st4EventNotificationsGroup(100) | +- .100 | | +--st4Compliances(2) +- .2 | | +--st4ModuleCompliances(1) +- .1