+--pdu2(6) | +--traps(0) | | | +--trapInformation(0) | | | | | +--trapInformationTable(1) | | | | | | | +--trapInformationEntry(1) | | | | Index: pduId | | | | | | | +-- ---N String userName(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- ---N String targetUser(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- ---N String imageVersion(5) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- ---N String roleName(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- ---N String smtpMessageRecipients(7) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- ---N String smtpServer(8) | | | Textual Convention: DisplayString | | | Size: 0..255 | | | | | +-- ---N EnumVal oldSensorState(2) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- ---N Integer32 pduNumber(3) | | | Range: 1..256 | | +-- ---N Integer32 inletPoleNumber(5) | | | Range: 1..256 | | +-- ---N Integer32 outletPoleNumber(7) | | | Range: 1..256 | | +-- ---N Integer32 externalSensorNumber(8) | | | Range: 1..256 | | +-- ---N EnumVal typeOfSensor(10) | | | Textual Convention: SensorTypeEnumeration | | | Values: rmsCurrent(1), peakCurrent(2), unbalancedCurrent(3), rmsVoltage(4), activePower(5), apparentPower(6), powerFactor(7), activeEnergy(8), apparentEnergy(9), temperature(10), humidity(11), airFlow(12), airPressure(13), onOff(14), trip(15), vibration(16), waterDetection(17), smokeDetection(18), binary(19), contact(20), fanSpeed(21), surgeProtectorStatus(22), frequency(23), phaseAngle(24), rmsVoltageLN(25), residualCurrent(26), rcmState(27), absoluteHumidity(28), reactivePower(29), other(30), none(31), powerQuality(32), overloadStatus(33), overheatStatus(34), displacementPowerFactor(35), residualDcCurrent(36), fanStatus(37), inletPhaseSyncAngle(38), inletPhaseSync(39), operatingState(40), activeInlet(41), illuminance(42), doorContact(43), tamperDetection(44), motionDetection(45), i1smpsStatus(46), i2smpsStatus(47), switchStatus(48), doorLockState(49), doorHandleLock(50), crestFactor(51) | | +-- ---N String errorDescription(11) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N EnumVal deviceChangedParameter(12) | | | Textual Convention: DeviceIdentificationParameterEnumeration | | | Values: pduName(0), sysContact(1), sysName(2), sysLocation(3) | | +-- ---N String changedParameterNewValue(13) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N EnumVal lhxSupportEnabled(14) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- ---N String webcamModel(15) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String webcamConnectionPort(16) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N Unsigned agentInetPortNumber(18) | | | Textual Convention: InetPortNumber | | | Range: 0..65535 | | +-- ---N String peripheralDeviceRomcode(19) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N EnumVal peripheralDeviceFirmwareUpdateState(20) | | | Textual Convention: PeripheralDeviceFirmwareUpdateStateEnumeration | | | Values: started(1), successful(2), failed(3) | | +-- ---N Integer32 circuitNumber(21) | | | Range: 1..33000 | | +-- ---N Integer32 circuitPoleNumber(22) | | | Range: 1..256 | | +-- ---N String phoneNumber(23) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String smartCardReaderId(24) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N Unsigned smartCardTimestamp(25) | | +-- ---N String smartCardType(26) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String smartCardId(27) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String suspectedTripCauseLabel(28) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String smartCardReaderManufacturer(29) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String smartCardReaderProduct(30) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String smartCardReaderSerialNumber(31) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N Integer32 smartCardReaderChannel(32) | | | Range: -1..256 | | +-- ---N Integer32 outletGroupNumber(33) | | | Range: 1..256 | | +-- ---N String serverPowerOperation(34) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N EnumVal serverPowerResult(35) | | | Textual Convention: ServerPowerControlResultEnumeration | | | Values: noError(0), shutdownCmdFailed(1), switchingOffFailed(2), switchingOnFailed(3), powerCheckTimeout(4) | | +-- ---N String webcamName(36) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- ---N String webcamFolderUrl(37) | | Textual Convention: DisplayString | | Size: 0..255 | | | +--systemStarted(1) | +--systemReset(2) | +--userLogin(3) | +--userLogout(4) | +--userAuthenticationFailure(5) | +--userSessionTimeout(8) | +--userAdded(11) | +--userModified(12) | +--userDeleted(13) | +--roleAdded(14) | +--roleModified(15) | +--roleDeleted(16) | +--deviceUpdateStarted(20) | +--deviceUpdateCompleted(21) | +--userBlocked(22) | +--powerControl(23) | +--userPasswordChanged(24) | +--passwordSettingsChanged(28) | +--firmwareValidationFailed(38) | +--logFileCleared(41) | +--bulkConfigurationSaved(53) | +--bulkConfigurationCopied(54) | +--pduSensorStateChange(60) | +--inletSensorStateChange(61) | +--inletPoleSensorStateChange(62) | +--outletSensorStateChange(63) | +--outletPoleSensorStateChange(64) | +--overCurrentProtectorSensorStateChange(65) | +--externalSensorStateChange(66) | +--smtpMessageTransmissionFailure(67) | +--ldapError(68) | +--deviceUpdateFailed(70) | +--loadSheddingModeEntered(71) | +--loadSheddingModeExited(72) | +--pingServerEnabled(73) | +--pingServerDisabled(74) | +--serverNotReachable(75) | +--serverReachable(76) | +--rfCodeTagConnected(77) | +--rfCodeTagDisconnected(78) | +--deviceIdentificationChanged(79) | +--usbSlaveConnected(80) | +--usbSlaveDisconnected(81) | +--lhxSupportChanged(82) | +--userAcceptedRestrictedServiceAgreement(83) | +--userDeclinedRestrictedServiceAgreement(84) | +--wireSensorStateChange(85) | +--transferSwitchSensorStateChange(86) | +--deviceSettingsSaved(88) | +--deviceSettingsRestored(89) | +--webcamInserted(90) | +--webcamRemoved(91) | +--inletEnabled(92) | +--inletDisabled(93) | +--serverConnectivityUnrecoverable(94) | +--radiusError(95) | +--serverReachabilityError(96) | +--inletSensorReset(97) | +--outletSensorReset(98) | +--unknownPeripheralDeviceAttached(99) | +--peripheralDeviceFirmwareUpdate(100) | +--unitSensorReset(101) | +--unitSensorStateChange(102) | +--circuitSensorStateChange(103) | +--circuitPoleSensorStateChange(104) | +--circuitAdded(105) | +--circuitDeleted(106) | +--circuitModified(107) | +--circuitSensorReset(108) | +--powerMeterAdded(109) | +--powerMeterDeleted(110) | +--powerMeterModified(111) | +--smsMessageTransmissionFailure(112) | +--smartCardInserted(113) | +--smartCardRemoved(114) | +--rawConfigurationDownloaded(115) | +--rawConfigurationUpdated(116) | +--hwFailureStatusChanged(117) | +--outletGroupAdded(118) | +--outletGroupModified(119) | +--outletGroupDeleted(120) | +--outletGroupSensorStateChange(121) | +--outletGroupSensorReset(122) | +--outletGroupPowerControl(123) | +--serverPowerControlInitiated(124) | +--serverPowerControlCompleted(125) | +--webcamStorageUploadStarted(126) | +--testEventTriggered(127) | +--actuatorSwitched(128) | +--board(1) | +--environmental(2) | +--configuration(3) | | | +-- -R-- Integer32 pduCount(1) | | | +--unit(2) | | | | | +--nameplateTable(1) | | | | | | | +--nameplateEntry(1) | | | | Index: pduId | | | | | | | +-- ---- Integer32 pduId(1) | | | | Range: 0..256 | | | +-- -R-- String pduManufacturer(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduModel(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduSerialNumber(4) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduRatedVoltage(5) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduRatedCurrent(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduRatedFrequency(7) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduRatedVA(8) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String pduImage(9) | | | Textual Convention: URL | | | Size: 0..255 | | | | | +--unitConfigurationTable(2) | | | | | | | +--unitConfigurationEntry(1) | | | | Index: pduId | | | | | | | +-- -R-- Integer32 inletCount(2) | | | | Range: 0..256 | | | +-- -R-- Integer32 overCurrentProtectorCount(3) | | | | Range: 0..255 | | | +-- -R-- Integer32 outletCount(4) | | | | Range: 0..256 | | | +-- -R-- Integer32 inletControllerCount(5) | | | | Range: 0..255 | | | +-- -R-- Integer32 outletControllerCount(6) | | | | Range: 0..255 | | | +-- -R-- Integer32 externalSensorCount(7) | | | | Range: 0..255 | | | +-- -R-- IpAddr pxIPAddress(8) | | | +-- -R-- IpAddr netmask(9) | | | +-- -R-- IpAddr gateway(10) | | | +-- -R-- String pxMACAddress(11) | | | | Textual Convention: MacAddress | | | | Size: 6 | | | +-- -R-- String utcOffset(12) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String pduName(13) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- EnumVal networkInterfaceType(14) | | | | Textual Convention: NetworkInterfaceTypeEnumeration | | | | Values: wired(0), wireless(1) | | | +-- -RW- EnumVal externalSensorsZCoordinateUnits(34) | | | | Textual Convention: ExternalSensorsZCoordinateUnitsEnumeration | | | | Values: rackUnits(0), text(1) | | | +-- -R-- BitString unitDeviceCapabilities(35) | | | | Values: activePower(4), activeEnergy(7), i1smpsStatus(45), i2smpsStatus(46) | | | +-- -RW- Unsigned outletSequencingDelay(36) | | | | Range: 100..10000 | | | +-- -RW- Unsigned globalOutletPowerCyclingPowerOffPeriod(37) | | | | Range: 1..3600 | | | +-- -RW- EnumVal globalOutletStateOnStartup(38) | | | | Textual Convention: GlobalOutletStateOnStartupEnumeration | | | | Values: off(0), on(1), lastKnownState(2) | | | +-- -RW- String outletPowerupSequence(39) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- Unsigned pduPowerCyclingPowerOffPeriod(40) | | | | Range: 1..3600 | | | +-- -R-- EnumVal pduDaisychainMemberType(41) | | | | Textual Convention: DaisychainMemberTypeEnumeration | | | | Values: standalone(0), master(1), slave(2) | | | +-- -R-- Integer32 managedExternalSensorCount(42) | | | | Range: 0..255 | | | +-- -R-- EnumVal pxInetAddressType(50) | | | | Textual Convention: InetAddressType | | | | Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16) | | | +-- -R-- String pxInetIPAddress(51) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -R-- String pxInetNetmask(52) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -R-- String pxInetGateway(53) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -RW- EnumVal loadShedding(55) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- Integer32 serverCount(56) | | | | Range: 0..255 | | | +-- -RW- Unsigned inrushGuardDelay(57) | | | | Range: 100..10000 | | | +-- -R-- EnumVal cascadedDeviceConnected(58) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal synchronizeWithNTPServer(59) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal useDHCPProvidedNTPServer(60) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal firstNTPServerAddressType(61) | | | | Textual Convention: InetAddressType | | | | Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16) | | | +-- -RW- String firstNTPServerAddress(62) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -RW- EnumVal secondNTPServerAddressType(63) | | | | Textual Convention: InetAddressType | | | | Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16) | | | +-- -RW- String secondNTPServerAddress(64) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -R-- Integer32 wireCount(65) | | | | Range: 0..255 | | | +-- -R-- Integer32 transferSwitchCount(66) | | | | Range: 0..255 | | | +-- -R-- EnumVal productType(67) | | | | Textual Convention: ProductTypeEnumeration | | | | Values: rackPdu(0), bcm(1), transferSwitch(2), powerMeter(3) | | | +-- -R-- Integer32 meteringControllerCount(68) | | | | Range: 0..255 | | | +-- -RW- EnumVal relayBehaviorOnPowerLoss(69) | | | | Textual Convention: RelayPowerLossBehaviorEnumeration | | | | Values: nonLatching(0), latching(1) | | | +-- -R-- EnumVal deviceCascadeType(70) | | | | Textual Convention: DeviceCascadeTypeEnumeration | | | | Values: bridging(0), portForwarding(1), none(2) | | | +-- -R-- Integer32 deviceCascadePosition(71) | | | | Range: 0..99 | | | +-- -RW- EnumVal peripheralDevicesAutoManagement(72) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal frontPanelOutletSwitching(73) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal frontPanelRCMSelfTest(74) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal frontPanelActuatorControl(75) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- Integer32 circuitCount(76) | | | | Range: 0..96 | | | +-- -R-- Integer32 activeDNSServerCount(77) | | | | Range: 0..16 | | | +-- -R-- Integer32 activeNTPServerCount(78) | | | | Range: 0..16 | | | +-- -R-- Integer32 peripheralDevicePackageCount(79) | | | | Range: 0..256 | | | +-- -R-- Integer32 outletGroupCount(80) | | | Range: 0..128 | | | | | +--controllerConfigurationTable(3) | | | | | | | +--controllerConfigurationEntry(1) | | | | Index: pduId, boardType, boardIndex | | | | | | | +-- ---- EnumVal boardType(1) | | | | Textual Convention: BoardTypeEnumeration | | | | Values: mainController(1), inletController(2), outletController(3), meteringController(4) | | | +-- ---- Integer32 boardIndex(2) | | | | Range: 1..256 | | | +-- -R-- String boardVersion(4) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String boardFirmwareVersion(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- Unsigned boardFirmwareTimeStamp(8) | | | | | +--logConfigurationTable(4) | | | | | | | +--logConfigurationEntry(1) | | | | Index: pduId | | | | | | | +-- -RW- EnumVal dataLogging(1) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- Integer32 measurementPeriod(2) | | | +-- -RW- Integer32 measurementsPerLogEntry(3) | | | | Range: 1..600 | | | +-- -R-- Integer32 logSize(4) | | | +-- -RW- EnumVal dataLoggingEnableForAllSensors(5) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | | | | +--unitSensorConfigurationTable(5) | | | | | | | +--unitSensorConfigurationEntry(1) | | | | Index: pduId, sensorType | | | | | | | +-- ---- EnumVal sensorType(1) | | | | Textual Convention: SensorTypeEnumeration | | | | Values: rmsCurrent(1), peakCurrent(2), unbalancedCurrent(3), rmsVoltage(4), activePower(5), apparentPower(6), powerFactor(7), activeEnergy(8), apparentEnergy(9), temperature(10), humidity(11), airFlow(12), airPressure(13), onOff(14), trip(15), vibration(16), waterDetection(17), smokeDetection(18), binary(19), contact(20), fanSpeed(21), surgeProtectorStatus(22), frequency(23), phaseAngle(24), rmsVoltageLN(25), residualCurrent(26), rcmState(27), absoluteHumidity(28), reactivePower(29), other(30), none(31), powerQuality(32), overloadStatus(33), overheatStatus(34), displacementPowerFactor(35), residualDcCurrent(36), fanStatus(37), inletPhaseSyncAngle(38), inletPhaseSync(39), operatingState(40), activeInlet(41), illuminance(42), doorContact(43), tamperDetection(44), motionDetection(45), i1smpsStatus(46), i2smpsStatus(47), switchStatus(48), doorLockState(49), doorHandleLock(50), crestFactor(51) | | | +-- -RW- EnumVal unitSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal unitSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned unitSensorDecimalDigits(7) | | | +-- -R-- Unsigned unitSensorAccuracy(8) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned unitSensorResolution(9) | | | +-- -R-- Unsigned unitSensorTolerance(10) | | | +-- -R-- Unsigned unitSensorMaximum(11) | | | +-- -R-- Unsigned unitSensorMinimum(12) | | | +-- -RW- Unsigned unitSensorHysteresis(13) | | | +-- -RW- Unsigned unitSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned unitSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned unitSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned unitSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned unitSensorUpperWarningThreshold(24) | | | +-- -RW- BitString unitSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 unitSensorSignedMaximum(26) | | | +-- -R-- Integer32 unitSensorSignedMinimum(27) | | | +-- -RW- Integer32 unitSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 unitSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 unitSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 unitSensorSignedUpperWarningThreshold(31) | | | | | +--activeDNSServerTable(6) | | | | | | | +--activeDNSServerEntry(1) | | | | Index: pduId, activeDNSServerIndex | | | | | | | +-- ---- Integer32 activeDNSServerIndex(2) | | | | Range: 1..16 | | | +-- -R-- EnumVal activeDNSServerAddressType(3) | | | | Textual Convention: InetAddressType | | | | Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16) | | | +-- -R-- String activeDNSServerAddress(4) | | | | Textual Convention: InetAddress | | | | Size: 0..255 | | | +-- -R-- EnumVal activeDNSServerAddressSource(5) | | | Textual Convention: AddressSourceEnumeration | | | Values: static(1), dhcp(2), dhcpv6(3) | | | | | +--activeNTPServerTable(7) | | | | | +--activeNTPServerEntry(1) | | | Index: pduId, activeNTPServerIndex | | | | | +-- ---- Integer32 activeNTPServerIndex(2) | | | Range: 1..16 | | +-- -R-- EnumVal activeNTPServerAddressType(3) | | | Textual Convention: InetAddressType | | | Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16) | | +-- -R-- String activeNTPServerAddress(4) | | | Textual Convention: InetAddress | | | Size: 0..255 | | +-- -R-- EnumVal activeNTPServerAddressSource(5) | | Textual Convention: AddressSourceEnumeration | | Values: static(1), dhcp(2), dhcpv6(3) | | | +--inlets(3) | | | | | +--inletConfigurationTable(3) | | | | | | | +--inletConfigurationEntry(1) | | | | Index: pduId, inletId | | | | | | | +-- ---- Integer32 inletId(1) | | | | Range: 1..256 | | | +-- -R-- String inletLabel(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String inletName(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- EnumVal inletPlug(4) | | | | Textual Convention: PlugTypeEnumeration | | | | Values: plugOTHER(-1), plugNONE(0), plug56P320(1), plug56P520(2), plug56P532(3), plugCS8365C(4), plugIEC320C14(5), plugIEC320C20(6), plugIEC603093WIRE250V16A(7), plugIEC603093WIRE250V20A(8), plugIEC603093WIRE250V30A(9), plugIEC603093WIRE250V32A(10), plugIEC603093WIRE250V60A(11), plugIEC603093WIRE250V63A(12), plugIEC603093WIRE250V100A(13), plugIEC603093WIRE250V125A(14), plugIEC603094WIRE250V20A(15), plugIEC603094WIRE250V30A(16), plugIEC603094WIRE250V60A(17), plugIEC603094WIRE250V100A(18), plugIEC603095WIRE208V20A(23), plugIEC603095WIRE208V30A(24), plugIEC603095WIRE208V60A(25), plugIEC603095WIRE208V100A(26), plugIEC603095WIRE415V16A(27), plugIEC603095WIRE415V32A(28), plugIEC603095WIRE415V63A(29), plugIEC603095WIRE415V125A(30), plugIEC603095WIRE480V20A(31), plugIEC603095WIRE480V30A(32), plugIEC603095WIRE480V60A(33), plugIEC603095WIRE480V100A(34), plugNEMA515P(35), plugNEMAL515P(36), plugNEMA520P(37), plugNEMAL520P(38), plugNEMAL530P(39), plugNEMAL615P(40), plugNEMAL620P(41), plugNEMAL630P(42), plugNEMAL1520P(43), plugNEMAL1530P(44), plugNEMAL2120P(45), plugNEMAL2130P(46), plugNEMAL2230P(47), plug56P320F(48), plug56PA320(49) | | | +-- -R-- Integer32 inletPoleCount(5) | | | | Range: 2..5 | | | +-- -R-- String inletRatedVoltage(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String inletRatedCurrent(7) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String inletRatedFrequency(8) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String inletRatedVA(9) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- BitString inletDeviceCapabilities(10) | | | | Values: rmsCurrent(0), peakCurrent(1), unbalancedCurrent(2), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), surgeProtectorStatus(21), frequency(22), phaseAngle(23), residualCurrent(25), rcmState(26), reactivePower(28), powerQuality(31), displacementPowerFactor(34), residualDcCurrent(35), crestFactor(50) | | | +-- -R-- BitString inletPoleCapabilities(11) | | | | Values: rmsCurrent(0), peakCurrent(1), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), phaseAngle(23), rmsVoltageLN(24), residualCurrent(25), rcmState(26), reactivePower(28), displacementPowerFactor(34), residualDcCurrent(35), crestFactor(50) | | | +-- -R-- String inletPlugDescriptor(12) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- EnumVal inletEnableState(13) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- Unsigned inletRCMResidualOperatingCurrent(14) | | | | | +--inletSensorConfigurationTable(4) | | | | | | | +--inletSensorConfigurationEntry(1) | | | | Index: pduId, inletId, sensorType | | | | | | | +-- -RW- EnumVal inletSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal inletSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned inletSensorDecimalDigits(7) | | | +-- -R-- Unsigned inletSensorAccuracy(8) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned inletSensorResolution(9) | | | +-- -R-- Unsigned inletSensorTolerance(10) | | | +-- -R-- Unsigned inletSensorMaximum(11) | | | +-- -R-- Unsigned inletSensorMinimum(12) | | | +-- -RW- Unsigned inletSensorHysteresis(13) | | | +-- -RW- Unsigned inletSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned inletSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned inletSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned inletSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned inletSensorUpperWarningThreshold(24) | | | +-- -RW- BitString inletSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 inletSensorSignedMaximum(26) | | | +-- -R-- Integer32 inletSensorSignedMinimum(27) | | | +-- -RW- Integer32 inletSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 inletSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 inletSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 inletSensorSignedUpperWarningThreshold(31) | | | | | +--inletPoleConfigurationTable(5) | | | | | | | +--inletPoleConfigurationEntry(1) | | | | Index: pduId, inletId, inletPoleIndex | | | | | | | +-- -R-- EnumVal inletPoleLine(1) | | | | Textual Convention: LineEnumeration | | | | Values: lineL1(1), lineL2(2), lineL3(3), lineNeutral(4) | | | +-- -R-- Integer32 inletPoleNode(2) | | | | | +--inletPoleSensorConfigurationTable(6) | | | | | +--inletPoleSensorConfigurationEntry(1) | | | Index: pduId, inletId, inletPoleIndex, sensorType | | | | | +-- ---- Integer32 inletPoleIndex(1) | | | Range: 1..256 | | +-- -RW- EnumVal inletPoleSensorLogAvailable(4) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal inletPoleSensorUnits(6) | | | Textual Convention: SensorUnitsEnumeration | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | +-- -R-- Unsigned inletPoleSensorDecimalDigits(7) | | +-- -R-- Unsigned inletPoleSensorAccuracy(8) | | | Textual Convention: HundredthsOfAPercentage | | | Range: 0..10000 | | +-- -R-- Unsigned inletPoleSensorResolution(9) | | +-- -R-- Unsigned inletPoleSensorTolerance(10) | | +-- -R-- Unsigned inletPoleSensorMaximum(11) | | +-- -R-- Unsigned inletPoleSensorMinimum(12) | | +-- -RW- Unsigned inletPoleSensorHysteresis(13) | | +-- -RW- Unsigned inletPoleSensorStateChangeDelay(14) | | | Range: 0..300 | | +-- -RW- Unsigned inletPoleSensorLowerCriticalThreshold(21) | | +-- -RW- Unsigned inletPoleSensorLowerWarningThreshold(22) | | +-- -RW- Unsigned inletPoleSensorUpperCriticalThreshold(23) | | +-- -RW- Unsigned inletPoleSensorUpperWarningThreshold(24) | | +-- -RW- BitString inletPoleSensorEnabledThresholds(25) | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | +-- -R-- Integer32 inletPoleSensorSignedMaximum(26) | | +-- -R-- Integer32 inletPoleSensorSignedMinimum(27) | | +-- -RW- Integer32 inletPoleSensorSignedLowerCriticalThreshold(28) | | +-- -RW- Integer32 inletPoleSensorSignedLowerWarningThreshold(29) | | +-- -RW- Integer32 inletPoleSensorSignedUpperCriticalThreshold(30) | | +-- -RW- Integer32 inletPoleSensorSignedUpperWarningThreshold(31) | | | +--overCurrentProtector(4) | | | | | +--overCurrentProtectorConfigurationTable(3) | | | | | | | +--overCurrentProtectorConfigurationEntry(1) | | | | Index: pduId, overCurrentProtectorIndex | | | | | | | +-- ---- Integer32 overCurrentProtectorIndex(1) | | | | Range: 1..256 | | | +-- -R-- String overCurrentProtectorLabel(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String overCurrentProtectorName(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- EnumVal overCurrentProtectorType(4) | | | | Textual Convention: OverCurrentProtectorTypeEnumeration | | | | Values: ocpBREAKER1POLE(1), ocpBREAKER2POLE(2), ocpBREAKER3POLE(3), ocpFUSE(4), ocpFUSEPAIR(5), ocpRCBO2POLE(6), ocpRCBO3POLE(7), ocpRCBO4POLE(8) | | | +-- -R-- String overCurrentProtectorRatedCurrent(5) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- Integer32 overCurrentProtectorPoleCount(6) | | | | Range: 1..3 | | | +-- -R-- BitString overCurrentProtectorCapabilities(9) | | | | Values: rmsCurrent(0), peakCurrent(1), trip(14) | | | +-- -R-- ObjID overCurrentProtectorPowerSource(10) | | | Textual Convention: RowPointer | | | | | +--overCurrentProtectorSensorConfigurationTable(4) | | | | | | | +--overCurrentProtectorSensorConfigurationEntry(1) | | | | Index: pduId, overCurrentProtectorIndex, sensorType | | | | | | | +-- -RW- EnumVal overCurrentProtectorSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal overCurrentProtectorSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned overCurrentProtectorSensorDecimalDigits(7) | | | +-- -R-- Unsigned overCurrentProtectorSensorAccuracy(8) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned overCurrentProtectorSensorResolution(9) | | | +-- -R-- Unsigned overCurrentProtectorSensorTolerance(10) | | | +-- -R-- Unsigned overCurrentProtectorSensorMaximum(11) | | | +-- -R-- Unsigned overCurrentProtectorSensorMinimum(12) | | | +-- -RW- Unsigned overCurrentProtectorSensorHysteresis(13) | | | +-- -RW- Unsigned overCurrentProtectorSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned overCurrentProtectorSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned overCurrentProtectorSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned overCurrentProtectorSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned overCurrentProtectorSensorUpperWarningThreshold(24) | | | +-- -RW- BitString overCurrentProtectorSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 overCurrentProtectorSensorSignedMaximum(26) | | | +-- -R-- Integer32 overCurrentProtectorSensorSignedMinimum(27) | | | +-- -RW- Integer32 overCurrentProtectorSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 overCurrentProtectorSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 overCurrentProtectorSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 overCurrentProtectorSensorSignedUpperWarningThreshold(31) | | | | | +--overCurrentProtectorPoleConfigurationTable(5) | | | | | +--overCurrentProtectorPoleConfigurationEntry(1) | | | Index: pduId, overCurrentProtectorIndex, overCurrentProtectorPoleIndex | | | | | +-- ---- Integer32 overCurrentProtectorPoleIndex(1) | | | Range: 1..256 | | +-- -R-- EnumVal overCurrentProtectorPoleLine(2) | | | Textual Convention: LineEnumeration | | | Values: lineL1(1), lineL2(2), lineL3(3), lineNeutral(4) | | +-- -R-- Integer32 overCurrentProtectorPoleInNode(3) | | +-- -R-- Integer32 overCurrentProtectorPoleOutNode(4) | | | +--outlets(5) | | | | | +--outletConfigurationTable(3) | | | | | | | +--outletConfigurationEntry(1) | | | | Index: pduId, outletId | | | | | | | +-- ---- Integer32 outletId(1) | | | | Range: 1..256 | | | +-- -R-- String outletLabel(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String outletName(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- EnumVal outletReceptacle(4) | | | | Textual Convention: ReceptacleTypeEnumeration | | | | Values: receptacleOTHER(-1), receptacleNONE(0), receptacleBS1363(1), receptacle56P532(3), receptacleCS8364C(4), receptacleIEC320C13(5), receptacleIEC320C19(6), receptacleIEC603093WIRE250V16A(7), receptacleIEC603093WIRE250V20A(8), receptacleIEC603093WIRE250V30A(9), receptacleIEC603093WIRE250V32A(10), receptacleIEC603093WIRE250V60A(11), receptacleIEC603093WIRE250V63A(12), receptacleIEC603093WIRE250V100A(13), receptacleIEC603093WIRE250V125A(14), receptacleIEC603094WIRE250V20A(15), receptacleIEC603094WIRE250V30A(16), receptacleIEC603094WIRE250V60A(17), receptacleIEC603094WIRE250V100A(18), receptacleIEC603095WIRE208V20A(23), receptacleIEC603095WIRE208V30A(24), receptacleIEC603095WIRE208V60A(25), receptacleIEC603095WIRE208V100A(26), receptacleIEC603095WIRE415V16A(27), receptacleIEC603095WIRE415V32A(28), receptacleIEC603095WIRE415V63A(29), receptacleIEC603095WIRE415V125A(30), receptacleIEC603095WIRE480V20A(31), receptacleIEC603095WIRE480V30A(32), receptacleIEC603095WIRE480V60A(33), receptacleIEC603095WIRE480V100A(34), receptacleNEMA515R(35), receptacleNEMAL515R(36), receptacleNEMA520R(37), receptacleNEMAL520R(38), receptacleNEMAL530R(39), receptacleNEMAL615R(40), receptacleNEMAL620R(41), receptacleNEMAL630R(42), receptacleNEMAL1520R(43), receptacleNEMAL1530R(44), receptacleNEMAL2120RP(45), receptacleNEMAL2130R(46), receptacleSCHUKOTYPEE(47), receptacleSCHUKOTYPEF(48) | | | +-- -R-- Integer32 outletPoleCount(5) | | | | Range: 2..4 | | | +-- -R-- String outletRatedVoltage(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String outletRatedCurrent(7) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- String outletRatedVA(8) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- BitString outletDeviceCapabilities(10) | | | | Values: rmsCurrent(0), peakCurrent(1), unbalancedCurrent(2), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), onOff(13), frequency(22), phaseAngle(23), reactivePower(28), displacementPowerFactor(34), crestFactor(50) | | | +-- -R-- BitString outletPoleCapabilities(11) | | | | Values: rmsCurrent(0), peakCurrent(1), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), phaseAngle(23), rmsVoltageLN(24), reactivePower(28), displacementPowerFactor(34), crestFactor(50) | | | +-- -RW- Unsigned outletPowerCyclingPowerOffPeriod(12) | | | | Range: 1..3600 | | | +-- -RW- EnumVal outletStateOnStartup(13) | | | | Textual Convention: OutletStateOnStartupEnumeration | | | | Values: off(0), on(1), lastKnownState(2), globalOutletStateOnStartup(3) | | | +-- -RW- EnumVal outletUseGlobalPowerCyclingPowerOffPeriod(14) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal outletSwitchable(28) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- String outletReceptacleDescriptor(29) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- EnumVal outletNonCritical(30) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- Unsigned outletSequenceDelay(32) | | | | Range: 0..3600 | | | +-- -R-- ObjID outletPowerSource(33) | | | Textual Convention: RowPointer | | | | | +--outletSensorConfigurationTable(4) | | | | | | | +--outletSensorConfigurationEntry(1) | | | | Index: pduId, outletId, sensorType | | | | | | | +-- -RW- EnumVal outletSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal outletSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned outletSensorDecimalDigits(7) | | | +-- -R-- Unsigned outletSensorAccuracy(8) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned outletSensorResolution(9) | | | +-- -R-- Unsigned outletSensorTolerance(10) | | | +-- -R-- Unsigned outletSensorMaximum(11) | | | +-- -R-- Unsigned outletSensorMinimum(12) | | | +-- -RW- Unsigned outletSensorHysteresis(13) | | | +-- -RW- Unsigned outletSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned outletSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned outletSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned outletSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned outletSensorUpperWarningThreshold(24) | | | +-- -RW- BitString outletSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 outletSensorSignedMaximum(26) | | | +-- -R-- Integer32 outletSensorSignedMinimum(27) | | | +-- -RW- Integer32 outletSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 outletSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 outletSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 outletSensorSignedUpperWarningThreshold(31) | | | | | +--outletPoleConfigurationTable(5) | | | | | | | +--outletPoleConfigurationEntry(1) | | | | Index: pduId, outletId, outletPoleIndex | | | | | | | +-- -R-- EnumVal outletPoleLine(1) | | | | Textual Convention: LineEnumeration | | | | Values: lineL1(1), lineL2(2), lineL3(3), lineNeutral(4) | | | +-- -R-- Integer32 outletPoleNode(2) | | | | | +--outletPoleSensorConfigurationTable(6) | | | | | +--outletPoleSensorConfigurationEntry(1) | | | Index: pduId, outletId, outletPoleIndex, sensorType | | | | | +-- ---- Integer32 outletPoleIndex(1) | | | Range: 1..256 | | +-- -RW- EnumVal outletPoleSensorLogAvailable(4) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal outletPoleSensorUnits(6) | | | Textual Convention: SensorUnitsEnumeration | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | +-- -R-- Unsigned outletPoleSensorDecimalDigits(7) | | +-- -R-- Unsigned outletPoleSensorAccuracy(8) | | | Textual Convention: HundredthsOfAPercentage | | | Range: 0..10000 | | +-- -R-- Unsigned outletPoleSensorResolution(9) | | +-- -R-- Unsigned outletPoleSensorTolerance(10) | | +-- -R-- Unsigned outletPoleSensorMaximum(11) | | +-- -R-- Unsigned outletPoleSensorMinimum(12) | | +-- -RW- Unsigned outletPoleSensorHysteresis(13) | | +-- -RW- Unsigned outletPoleSensorStateChangeDelay(14) | | | Range: 0..300 | | +-- -RW- Unsigned outletPoleSensorLowerCriticalThreshold(21) | | +-- -RW- Unsigned outletPoleSensorLowerWarningThreshold(22) | | +-- -RW- Unsigned outletPoleSensorUpperCriticalThreshold(23) | | +-- -RW- Unsigned outletPoleSensorUpperWarningThreshold(24) | | +-- -RW- BitString outletPoleSensorEnabledThresholds(25) | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | +-- -R-- Integer32 outletPoleSensorSignedMaximum(26) | | +-- -R-- Integer32 outletPoleSensorSignedMinimum(27) | | +-- -RW- Integer32 outletPoleSensorSignedLowerCriticalThreshold(28) | | +-- -RW- Integer32 outletPoleSensorSignedLowerWarningThreshold(29) | | +-- -RW- Integer32 outletPoleSensorSignedUpperCriticalThreshold(30) | | +-- -RW- Integer32 outletPoleSensorSignedUpperWarningThreshold(31) | | | +--externalSensors(6) | | | | | +--externalSensorConfigurationTable(3) | | | | | | | +--externalSensorConfigurationEntry(1) | | | | Index: pduId, sensorID | | | | | | | +-- ---- Integer32 sensorID(1) | | | | Range: 1..256 | | | +-- -R-- EnumVal externalSensorType(2) | | | | Textual Convention: SensorTypeEnumeration | | | | Values: rmsCurrent(1), peakCurrent(2), unbalancedCurrent(3), rmsVoltage(4), activePower(5), apparentPower(6), powerFactor(7), activeEnergy(8), apparentEnergy(9), temperature(10), humidity(11), airFlow(12), airPressure(13), onOff(14), trip(15), vibration(16), waterDetection(17), smokeDetection(18), binary(19), contact(20), fanSpeed(21), surgeProtectorStatus(22), frequency(23), phaseAngle(24), rmsVoltageLN(25), residualCurrent(26), rcmState(27), absoluteHumidity(28), reactivePower(29), other(30), none(31), powerQuality(32), overloadStatus(33), overheatStatus(34), displacementPowerFactor(35), residualDcCurrent(36), fanStatus(37), inletPhaseSyncAngle(38), inletPhaseSync(39), operatingState(40), activeInlet(41), illuminance(42), doorContact(43), tamperDetection(44), motionDetection(45), i1smpsStatus(46), i2smpsStatus(47), switchStatus(48), doorLockState(49), doorHandleLock(50), crestFactor(51) | | | +-- -R-- String externalSensorSerialNumber(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String externalSensorName(4) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String externalSensorDescription(5) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String externalSensorXCoordinate(6) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String externalSensorYCoordinate(7) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String externalSensorZCoordinate(8) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- Integer32 externalSensorChannelNumber(9) | | | +-- -RW- EnumVal externalOnOffSensorSubtype(10) | | | | Textual Convention: SensorTypeEnumeration | | | | Values: rmsCurrent(1), peakCurrent(2), unbalancedCurrent(3), rmsVoltage(4), activePower(5), apparentPower(6), powerFactor(7), activeEnergy(8), apparentEnergy(9), temperature(10), humidity(11), airFlow(12), airPressure(13), onOff(14), trip(15), vibration(16), waterDetection(17), smokeDetection(18), binary(19), contact(20), fanSpeed(21), surgeProtectorStatus(22), frequency(23), phaseAngle(24), rmsVoltageLN(25), residualCurrent(26), rcmState(27), absoluteHumidity(28), reactivePower(29), other(30), none(31), powerQuality(32), overloadStatus(33), overheatStatus(34), displacementPowerFactor(35), residualDcCurrent(36), fanStatus(37), inletPhaseSyncAngle(38), inletPhaseSync(39), operatingState(40), activeInlet(41), illuminance(42), doorContact(43), tamperDetection(44), motionDetection(45), i1smpsStatus(46), i2smpsStatus(47), switchStatus(48), doorLockState(49), doorHandleLock(50), crestFactor(51) | | | +-- -RW- EnumVal externalSensorLogAvailable(14) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal externalSensorUnits(16) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned externalSensorDecimalDigits(17) | | | +-- -R-- Unsigned externalSensorAccuracy(18) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned externalSensorResolution(19) | | | +-- -R-- Unsigned externalSensorTolerance(20) | | | +-- -R-- Integer32 externalSensorMaximum(21) | | | +-- -R-- Integer32 externalSensorMinimum(22) | | | +-- -RW- Unsigned externalSensorHysteresis(23) | | | +-- -RW- Unsigned externalSensorStateChangeDelay(24) | | | | Range: 0..300 | | | +-- -RW- Integer32 externalSensorLowerCriticalThreshold(31) | | | +-- -RW- Integer32 externalSensorLowerWarningThreshold(32) | | | +-- -RW- Integer32 externalSensorUpperCriticalThreshold(33) | | | +-- -RW- Integer32 externalSensorUpperWarningThreshold(34) | | | +-- -RW- BitString externalSensorEnabledThresholds(35) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- EnumVal externalSensorIsActuator(36) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- String externalSensorPosition(37) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- EnumVal externalSensorUseDefaultThresholds(38) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- Integer32 externalSensorAlarmedToNormalDelay(39) | | | Range: 0..300 | | | | | +--externalSensorTypeDefaultThresholdsTable(4) | | | | | | | +--externalSensorTypeDefaultThresholdsEntry(1) | | | | Index: pduId, sensorType | | | | | | | +-- -RW- Unsigned externalSensorTypeDefaultHysteresis(3) | | | +-- -RW- Unsigned externalSensorTypeDefaultStateChangeDelay(4) | | | | Range: 0..300 | | | +-- -RW- Integer32 externalSensorTypeDefaultLowerCriticalThreshold(5) | | | +-- -RW- Integer32 externalSensorTypeDefaultLowerWarningThreshold(6) | | | +-- -RW- Integer32 externalSensorTypeDefaultUpperCriticalThreshold(7) | | | +-- -RW- Integer32 externalSensorTypeDefaultUpperWarningThreshold(8) | | | +-- -RW- BitString externalSensorTypeDefaultEnabledThresholds(9) | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | | | +--peripheralDevicePackageTable(5) | | | | | +--peripheralDevicePackageEntry(1) | | | Index: pduId, peripheralDevicePackageId | | | | | +-- ---- Integer32 peripheralDevicePackageId(1) | | | Range: 1..256 | | +-- -R-- String peripheralDevicePackageSerialNumber(3) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- String peripheralDevicePackageModel(4) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- String peripheralDevicePackageFirmwareVersion(5) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- String peripheralDevicePackageMinFirmwareVersion(6) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- Unsigned peripheralDevicePackageFirmwareTimeStamp(7) | | +-- -R-- String peripheralDevicePackagePosition(8) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- String peripheralDevicePackageState(9) | | Textual Convention: DisplayString | | Size: 0..255 | | | +--serverReachability(7) | | | | | +--serverReachabilityTable(3) | | | | | +--serverReachabilityEntry(1) | | | Index: pduId, serverID | | | | | +-- ---- Integer32 serverID(1) | | | Range: 1..256 | | +-- -R-- String serverIPAddress(3) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -RW- EnumVal serverPingEnabled(4) | | Textual Convention: TruthValue | | Values: true(1), false(2) | | | +--wires(8) | | | | | +--wireConfigurationTable(3) | | | | | | | +--wireConfigurationEntry(1) | | | | Index: pduId, wireId | | | | | | | +-- ---- Integer32 wireId(1) | | | | Range: 1..256 | | | +-- -R-- String wireLabel(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- BitString wireCapabilities(3) | | | | Values: rmsCurrent(0), peakCurrent(1), unbalancedCurrent(2), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8) | | | +-- -R-- ObjID wirePowerSource(4) | | | Textual Convention: RowPointer | | | | | +--wireSensorConfigurationTable(4) | | | | | +--wireSensorConfigurationEntry(1) | | | Index: pduId, wireId, sensorType | | | | | +-- -RW- EnumVal wireSensorLogAvailable(4) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal wireSensorUnits(6) | | | Textual Convention: SensorUnitsEnumeration | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | +-- -R-- Unsigned wireSensorDecimalDigits(7) | | +-- -R-- Unsigned wireSensorAccuracy(8) | | | Textual Convention: HundredthsOfAPercentage | | | Range: 0..10000 | | +-- -R-- Unsigned wireSensorResolution(9) | | +-- -R-- Unsigned wireSensorTolerance(10) | | +-- -R-- Unsigned wireSensorMaximum(11) | | +-- -R-- Unsigned wireSensorMinimum(12) | | +-- -RW- Unsigned wireSensorHysteresis(13) | | +-- -RW- Unsigned wireSensorStateChangeDelay(14) | | | Range: 0..300 | | +-- -RW- Unsigned wireSensorLowerCriticalThreshold(21) | | +-- -RW- Unsigned wireSensorLowerWarningThreshold(22) | | +-- -RW- Unsigned wireSensorUpperCriticalThreshold(23) | | +-- -RW- Unsigned wireSensorUpperWarningThreshold(24) | | +-- -RW- BitString wireSensorEnabledThresholds(25) | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +--transferSwitch(9) | | | | | +--transferSwitchConfigurationTable(3) | | | | | | | +--transferSwitchConfigurationEntry(1) | | | | Index: pduId, transferSwitchId | | | | | | | +-- ---- Integer32 transferSwitchId(1) | | | | Range: 1..256 | | | +-- -R-- String transferSwitchLabel(2) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -RW- String transferSwitchName(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- Integer32 transferSwitchPreferredInlet(4) | | | | Range: 1..64 | | | +-- -R-- Integer32 transferSwitchPoleCount(5) | | | | Range: 2..4 | | | +-- -RW- EnumVal transferSwitchAutoReTransferEnabled(20) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- Unsigned transferSwitchAutoReTransferWaitTime(21) | | | | Range: 1..180 | | | +-- -RW- EnumVal transferSwitchAutoReTransferRequiresPhaseSync(22) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -RW- EnumVal transferSwitchFrontPanelManualTransferButtonEnabled(23) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- BitString transferSwitchCapabilities(24) | | | | Values: overloadStatus(32), inletPhaseSyncAngle(37), inletPhaseSync(38), operatingState(39), activeInlet(40), switchStatus(47) | | | +-- -R-- ObjID transferSwitchPowerSource1(31) | | | | Textual Convention: RowPointer | | | +-- -R-- ObjID transferSwitchPowerSource2(32) | | | Textual Convention: RowPointer | | | | | +--transferSwitchSensorConfigurationTable(4) | | | | | | | +--transferSwitchSensorConfigurationEntry(1) | | | | Index: pduId, transferSwitchId, sensorType | | | | | | | +-- -RW- EnumVal transferSwitchSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal transferSwitchSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned transferSwitchSensorDecimalDigits(7) | | | +-- -R-- Unsigned transferSwitchSensorAccuracy(8) | | | | Textual Convention: HundredthsOfAPercentage | | | | Range: 0..10000 | | | +-- -R-- Unsigned transferSwitchSensorResolution(9) | | | +-- -R-- Unsigned transferSwitchSensorTolerance(10) | | | +-- -R-- Unsigned transferSwitchSensorMaximum(11) | | | +-- -R-- Unsigned transferSwitchSensorMinimum(12) | | | +-- -RW- Unsigned transferSwitchSensorHysteresis(13) | | | +-- -RW- Unsigned transferSwitchSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned transferSwitchSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned transferSwitchSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned transferSwitchSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned transferSwitchSensorUpperWarningThreshold(24) | | | +-- -RW- BitString transferSwitchSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 transferSwitchSensorSignedMaximum(26) | | | +-- -R-- Integer32 transferSwitchSensorSignedMinimum(27) | | | +-- -RW- Integer32 transferSwitchSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 transferSwitchSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 transferSwitchSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 transferSwitchSensorSignedUpperWarningThreshold(31) | | | | | +--transferSwitchPoleConfigurationTable(5) | | | | | +--transferSwitchPoleConfigurationEntry(1) | | | Index: pduId, transferSwitchId, transferSwitchPoleIndex | | | | | +-- ---- Integer32 transferSwitchPoleIndex(1) | | | Range: 1..256 | | +-- -R-- EnumVal transferSwitchPoleLine(2) | | | Textual Convention: LineEnumeration | | | Values: lineL1(1), lineL2(2), lineL3(3), lineNeutral(4) | | +-- -R-- Integer32 transferSwitchPoleIn1Node(3) | | +-- -R-- Integer32 transferSwitchPoleIn2Node(4) | | +-- -R-- Integer32 transferSwitchPoleOutNode(5) | | | +--powerMeter(10) | | | | | +--powerMeterConfigurationTable(2) | | | | | +--powerMeterConfigurationEntry(1) | | | Index: pduId | | | | | +-- -RW- Unsigned powerMeterPhaseCTRating(2) | | +-- -RW- Unsigned powerMeterNeutralCTRating(3) | | +-- -RW- Unsigned powerMeterEarthCTRating(4) | | +-- -R-- Unsigned powerMeterBranchCount(5) | | +-- -R-- Integer32 powerMeterPanelPositions(6) | | | Range: 0..256 | | +-- -R-- EnumVal powerMeterPanelLayout(7) | | | Textual Convention: PanelLayoutEnumeration | | | Values: invalid(-1), oneColumn(1), twoColumns(2) | | +-- -R-- EnumVal powerMeterPanelNumbering(8) | | | Textual Convention: PanelNumberingEnumeration | | | Values: invalid(-1), oddEven(1), sequential(2) | | +-- -R-- EnumVal powerMeterType(9) | | Textual Convention: PowerMeterTypeEnumeration | | Values: singlePhase(1), splitPhase(2), threePhase(3) | | | +--circuit(11) | | | | | +--circuitConfigurationTable(2) | | | | | | | +--circuitConfigurationEntry(1) | | | | Index: pduId, circuitId | | | | | | | +-- ---- Integer32 circuitId(1) | | | | Range: 1..1024 | | | +-- -R-- Integer32 circuitPoleCount(2) | | | | Range: 1..256 | | | +-- -RW- String circuitName(3) | | | | Textual Convention: DisplayString | | | | Size: 0..255 | | | +-- -R-- EnumVal circuitType(4) | | | | Textual Convention: CircuitTypeEnumeration | | | | Values: onePhaseLL(1), onePhaseLN(2), onePhaseLLN(3), threePhase(4) | | | +-- -RW- Unsigned circuitRatedCurrent(5) | | | +-- -RW- Unsigned circuitCTRating(6) | | | +-- -R-- BitString circuitCapabilities(7) | | | | Values: rmsCurrent(0), peakCurrent(1), unbalancedCurrent(2), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), surgeProtectorStatus(21), frequency(22), phaseAngle(23), residualCurrent(25), rcmState(26), reactivePower(28), powerQuality(31), displacementPowerFactor(34), crestFactor(50) | | | +-- -R-- BitString circuitPoleCapabilities(8) | | | | Values: rmsCurrent(0), peakCurrent(1), rmsVoltage(3), activePower(4), apparentPower(5), powerFactor(6), activeEnergy(7), apparentEnergy(8), phaseAngle(23), rmsVoltageLN(24), reactivePower(28), displacementPowerFactor(34), crestFactor(50) | | | +-- -R-- ObjID circuitPowerSource(9) | | | Textual Convention: RowPointer | | | | | +--circuitPoleConfigurationTable(3) | | | | | | | +--circuitPoleConfigurationEntry(1) | | | | Index: pduId, circuitId, circuitPoleId | | | | | | | +-- ---- Integer32 circuitPoleId(1) | | | | Range: 1..256 | | | +-- -R-- Integer32 circuitPolePanelPosition(2) | | | | Range: 1..256 | | | +-- -RW- Integer32 circuitPoleCTNumber(3) | | | | Range: 0..256 | | | +-- -RW- EnumVal circuitPolePhase(4) | | | Textual Convention: PhaseEnumeration | | | Values: phaseA(1), phaseB(2), phaseC(3), neutral(4), earth(5) | | | | | +--circuitSensorConfigurationTable(4) | | | | | | | +--circuitSensorConfigurationEntry(1) | | | | Index: pduId, circuitId, sensorType | | | | | | | +-- -RW- EnumVal circuitSensorLogAvailable(4) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal circuitSensorUnits(6) | | | | Textual Convention: SensorUnitsEnumeration | | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | | +-- -R-- Unsigned circuitSensorDecimalDigits(7) | | | +-- -R-- Unsigned circuitSensorResolution(9) | | | +-- -R-- Unsigned circuitSensorMaximum(11) | | | +-- -R-- Unsigned circuitSensorMinimum(12) | | | +-- -RW- Unsigned circuitSensorHysteresis(13) | | | +-- -RW- Unsigned circuitSensorStateChangeDelay(14) | | | | Range: 0..300 | | | +-- -RW- Unsigned circuitSensorLowerCriticalThreshold(21) | | | +-- -RW- Unsigned circuitSensorLowerWarningThreshold(22) | | | +-- -RW- Unsigned circuitSensorUpperCriticalThreshold(23) | | | +-- -RW- Unsigned circuitSensorUpperWarningThreshold(24) | | | +-- -RW- BitString circuitSensorEnabledThresholds(25) | | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | | +-- -R-- Integer32 circuitSensorSignedMaximum(26) | | | +-- -R-- Integer32 circuitSensorSignedMinimum(27) | | | +-- -RW- Integer32 circuitSensorSignedLowerCriticalThreshold(28) | | | +-- -RW- Integer32 circuitSensorSignedLowerWarningThreshold(29) | | | +-- -RW- Integer32 circuitSensorSignedUpperCriticalThreshold(30) | | | +-- -RW- Integer32 circuitSensorSignedUpperWarningThreshold(31) | | | | | +--circuitPoleSensorConfigurationTable(6) | | | | | +--circuitPoleSensorConfigurationEntry(1) | | | Index: pduId, circuitId, circuitPoleId, sensorType | | | | | +-- -RW- EnumVal circuitPoleSensorLogAvailable(4) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal circuitPoleSensorUnits(6) | | | Textual Convention: SensorUnitsEnumeration | | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | | +-- -R-- Unsigned circuitPoleSensorDecimalDigits(7) | | +-- -R-- Unsigned circuitPoleSensorResolution(9) | | +-- -R-- Unsigned circuitPoleSensorMaximum(11) | | +-- -R-- Unsigned circuitPoleSensorMinimum(12) | | +-- -RW- Unsigned circuitPoleSensorHysteresis(13) | | +-- -RW- Unsigned circuitPoleSensorStateChangeDelay(14) | | | Range: 0..300 | | +-- -RW- Unsigned circuitPoleSensorLowerCriticalThreshold(21) | | +-- -RW- Unsigned circuitPoleSensorLowerWarningThreshold(22) | | +-- -RW- Unsigned circuitPoleSensorUpperCriticalThreshold(23) | | +-- -RW- Unsigned circuitPoleSensorUpperWarningThreshold(24) | | +-- -RW- BitString circuitPoleSensorEnabledThresholds(25) | | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | | +-- -R-- Integer32 circuitPoleSensorSignedMaximum(26) | | +-- -R-- Integer32 circuitPoleSensorSignedMinimum(27) | | +-- -RW- Integer32 circuitPoleSensorSignedLowerCriticalThreshold(28) | | +-- -RW- Integer32 circuitPoleSensorSignedLowerWarningThreshold(29) | | +-- -RW- Integer32 circuitPoleSensorSignedUpperCriticalThreshold(30) | | +-- -RW- Integer32 circuitPoleSensorSignedUpperWarningThreshold(31) | | | +--outletGroups(12) | | | +--outletGroupConfigurationTable(2) | | | | | +--outletGroupConfigurationEntry(1) | | | Index: outletGroupId | | | | | +-- ---- Integer32 outletGroupId(1) | | | Range: 1..128 | | +-- -RW- String outletGroupName(2) | | | Textual Convention: DisplayString | | | Size: 0..255 | | +-- -R-- BitString outletGroupCapabilities(3) | | | Values: activePower(4), activeEnergy(7) | | +-- -RW- String outletGroupMembers(4) | | Textual Convention: DisplayString | | Size: 0..255 | | | +--outletGroupSensorConfigurationTable(3) | | | +--outletGroupSensorConfigurationEntry(1) | | Index: outletGroupId, sensorType | | | +-- -RW- EnumVal outletGroupSensorLogAvailable(4) | | Textual Convention: TruthValue | | Values: true(1), false(2) | +-- -R-- EnumVal outletGroupSensorUnits(6) | | Textual Convention: SensorUnitsEnumeration | | Values: none(-1), other(0), volt(1), amp(2), watt(3), voltamp(4), wattHour(5), voltampHour(6), degreeC(7), hertz(8), percent(9), meterpersec(10), pascal(11), psi(12), g(13), degreeF(14), feet(15), inches(16), cm(17), meters(18), rpm(19), degrees(20), lux(21), grampercubicmeter(22), var(23) | +-- -R-- Unsigned outletGroupSensorDecimalDigits(7) | +-- -R-- Unsigned outletGroupSensorResolution(9) | +-- -R-- Unsigned outletGroupSensorMaximum(11) | +-- -R-- Unsigned outletGroupSensorMinimum(12) | +-- -RW- Unsigned outletGroupSensorHysteresis(13) | +-- -RW- Unsigned outletGroupSensorStateChangeDelay(14) | +-- -RW- Unsigned outletGroupSensorLowerCriticalThreshold(21) | +-- -RW- Unsigned outletGroupSensorLowerWarningThreshold(22) | +-- -RW- Unsigned outletGroupSensorUpperCriticalThreshold(23) | +-- -RW- Unsigned outletGroupSensorUpperWarningThreshold(24) | +-- -RW- BitString outletGroupSensorEnabledThresholds(25) | | Values: lowerCritical(0), lowerWarning(1), upperWarning(2), upperCritical(3) | +-- -R-- Integer32 outletGroupSensorSignedMaximum(26) | +-- -R-- Integer32 outletGroupSensorSignedMinimum(27) | +-- -RW- Integer32 outletGroupSensorSignedLowerCriticalThreshold(28) | +-- -RW- Integer32 outletGroupSensorSignedLowerWarningThreshold(29) | +-- -RW- Integer32 outletGroupSensorSignedUpperCriticalThreshold(30) | +-- -RW- Integer32 outletGroupSensorSignedUpperWarningThreshold(31) | +--control(4) | | | +--outletControl(1) | | | | | +--outletSwitchControlTable(2) | | | | | +--outletSwitchControlEntry(1) | | | Index: pduId, outletId | | | | | +-- -RW- EnumVal switchingOperation(2) | | | Textual Convention: OutletSwitchingOperationsEnumeration | | | Values: off(0), on(1), cycle(2) | | +-- -R-- EnumVal outletSwitchingState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned outletSwitchingTimeStamp(4) | | | +--externalSensorControl(2) | | | +--transferSwitchControl(3) | | | | | +--transferSwitchControlTable(1) | | | | | +--transferSwitchControlEntry(1) | | | Index: pduId, transferSwitchId | | | | | +-- -R-- Integer32 transferSwitchActiveInlet(1) | | | Range: 1..64 | | +-- -RW- Integer32 transferSwitchTransferToInlet(2) | | | Range: 0..64 | | +-- -RW- EnumVal transferSwitchAlarmOverride(3) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal transferSwitchLastTransferReason(4) | | Textual Convention: TransferSwitchTransferReasonEnumeration | | Values: unknown(0), startup(1), manualTransfer(2), automaticReTransfer(3), powerFailure(4), powerQuality(5), overloadAlarm(6), overheatAlarm(7), internalFailure(8) | | | +--actuatorControl(4) | | | | | +--actuatorControlTable(2) | | | | | +--actuatorControlEntry(1) | | | Index: pduId, sensorID | | | | | +-- -RW- EnumVal actuatorState(2) | | Textual Convention: SensorStateEnumeration | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +--rcmControl(5) | | | | | +--rcmSelfTestTable(2) | | | | | +--rcmSelfTestEntry(1) | | | Index: pduId, inletId | | | | | +-- -RW- EnumVal rcmState(2) | | Textual Convention: SensorStateEnumeration | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +--inletSensorControl(6) | | | | | +--inletSensorControlTable(1) | | | | | +--inletSensorControlEntry(1) | | | Index: pduId, inletId, sensorType | | | | | +-- -RW- Integer32 inletSensorResetValue(1) | | | +--outletSensorControl(7) | | | | | +--outletSensorControlTable(1) | | | | | +--outletSensorControlEntry(1) | | | Index: pduId, outletId, sensorType | | | | | +-- -RW- Integer32 outletSensorResetValue(1) | | | +--unitSensorControl(8) | | | | | +--unitSensorControlTable(1) | | | | | +--unitSensorControlEntry(1) | | | Index: pduId, sensorType | | | | | +-- -RW- Integer32 unitSensorResetValue(1) | | | +--circuitSensorControl(9) | | | | | +--circuitSensorControlTable(1) | | | | | +--circuitSensorControlEntry(1) | | | Index: pduId, circuitId, sensorType | | | | | +-- -RW- Integer32 circuitSensorResetValue(1) | | | +--outletGroupControl(10) | | | | | +--outletGroupSwitchControlTable(2) | | | | | +--outletGroupSwitchControlEntry(1) | | | Index: outletGroupId | | | | | +-- -RW- EnumVal outletGroupSwitchingOperation(2) | | Textual Convention: OutletSwitchingOperationsEnumeration | | Values: off(0), on(1), cycle(2) | | | +--outletGroupSensorControl(11) | | | | | +--outletGroupSensorControlTable(1) | | | | | +--outletGroupSensorControlEntry(1) | | | Index: outletGroupId, sensorType | | | | | +-- -RW- Integer32 outletGroupSensorResetValue(1) | | | +--serverPowerControl(12) | | | +--serverPowerControlTable(1) | | | +--serverPowerControlEntry(1) | | Index: pduId, serverID | | | +-- -RW- EnumVal serverPowerControlOperation(1) | Textual Convention: ServerPowerStateEnumeration | Values: unknown(0), on(1), off(2), shuttingDown(3) | +--measurements(5) | | | +--measurementsUnit(1) | | | | | +--unitSensorMeasurementsTable(3) | | | | | +--unitSensorMeasurementsEntry(1) | | | Index: pduId, sensorType | | | | | +-- -R-- EnumVal measurementsUnitSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsUnitSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsUnitSensorValue(4) | | +-- -R-- Unsigned measurementsUnitSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsUnitSensorSignedValue(6) | | | +--measurementsInlet(2) | | | | | +--inletSensorMeasurementsTable(3) | | | | | | | +--inletSensorMeasurementsEntry(1) | | | | Index: pduId, inletId, sensorType | | | | | | | +-- -R-- EnumVal measurementsInletSensorIsAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal measurementsInletSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned measurementsInletSensorValue(4) | | | +-- -R-- Unsigned measurementsInletSensorTimeStamp(5) | | | +-- -R-- Integer32 measurementsInletSensorSignedValue(6) | | | | | +--inletPoleSensorMeasurementsTable(4) | | | | | +--inletPoleSensorMeasurementsEntry(1) | | | Index: pduId, inletId, inletPoleIndex, sensorType | | | | | +-- -R-- EnumVal measurementsInletPoleSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsInletPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsInletPoleSensorValue(4) | | +-- -R-- Unsigned measurementsInletPoleSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsInletPoleSensorSignedValue(6) | | | +--measurementsOverCurrentProtector(3) | | | | | +--overCurrentProtectorSensorMeasurementsTable(3) | | | | | +--overCurrentProtectorSensorMeasurementsEntry(1) | | | Index: pduId, overCurrentProtectorIndex, sensorType | | | | | +-- -R-- EnumVal measurementsOverCurrentProtectorSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsOverCurrentProtectorSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsOverCurrentProtectorSensorValue(4) | | +-- -R-- Unsigned measurementsOverCurrentProtectorSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsOverCurrentProtectorSensorSignedValue(6) | | | +--measurementsOutlet(4) | | | | | +--outletSensorMeasurementsTable(3) | | | | | | | +--outletSensorMeasurementsEntry(1) | | | | Index: pduId, outletId, sensorType | | | | | | | +-- -R-- EnumVal measurementsOutletSensorIsAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal measurementsOutletSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned measurementsOutletSensorValue(4) | | | +-- -R-- Unsigned measurementsOutletSensorTimeStamp(5) | | | +-- -R-- Integer32 measurementsOutletSensorSignedValue(6) | | | | | +--outletPoleSensorMeasurementsTable(4) | | | | | +--outletPoleSensorMeasurementsEntry(1) | | | Index: pduId, outletId, outletPoleIndex, sensorType | | | | | +-- -R-- EnumVal measurementsOutletPoleSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsOutletPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsOutletPoleSensorValue(4) | | +-- -R-- Unsigned measurementsOutletPoleSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsOutletPoleSensorSignedValue(6) | | | +--measurementsExternalSensor(5) | | | | | +--externalSensorMeasurementsTable(3) | | | | | +--externalSensorMeasurementsEntry(1) | | | Index: pduId, sensorID | | | | | +-- -R-- EnumVal measurementsExternalSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsExternalSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Integer32 measurementsExternalSensorValue(4) | | +-- -R-- Unsigned measurementsExternalSensorTimeStamp(5) | | | +--measurementsWire(6) | | | | | +--wireSensorMeasurementsTable(3) | | | | | +--wireSensorMeasurementsEntry(1) | | | Index: pduId, wireId, sensorType | | | | | +-- -R-- EnumVal measurementsWireSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsWireSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsWireSensorValue(4) | | +-- -R-- Unsigned measurementsWireSensorTimeStamp(5) | | | +--measurementsTransferSwitch(7) | | | | | +--transferSwitchSensorMeasurementsTable(3) | | | | | +--transferSwitchSensorMeasurementsEntry(1) | | | Index: pduId, transferSwitchId, sensorType | | | | | +-- -R-- EnumVal measurementsTransferSwitchSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsTransferSwitchSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsTransferSwitchSensorValue(4) | | +-- -R-- Unsigned measurementsTransferSwitchSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsTransferSwitchSensorSignedValue(6) | | | +--measurementsCircuit(8) | | | | | +--circuitSensorMeasurementsTable(3) | | | | | | | +--circuitSensorMeasurementsEntry(1) | | | | Index: pduId, circuitId, sensorType | | | | | | | +-- -R-- EnumVal measurementsCircuitSensorIsAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal measurementsCircuitSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned measurementsCircuitSensorValue(4) | | | +-- -R-- Unsigned measurementsCircuitSensorTimeStamp(5) | | | +-- -R-- Integer32 measurementsCircuitSensorSignedValue(6) | | | | | +--circuitPoleSensorMeasurementsTable(4) | | | | | +--circuitPoleSensorMeasurementsEntry(1) | | | Index: pduId, circuitId, circuitPoleId, sensorType | | | | | +-- -R-- EnumVal measurementsCircuitPoleSensorIsAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal measurementsCircuitPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned measurementsCircuitPoleSensorValue(4) | | +-- -R-- Unsigned measurementsCircuitPoleSensorTimeStamp(5) | | +-- -R-- Integer32 measurementsCircuitPoleSensorSignedValue(6) | | | +--measurementsOutletGroup(9) | | | +--outletGroupSensorMeasurementsTable(3) | | | +--outletGroupSensorMeasurementsEntry(1) | | Index: outletGroupId, sensorType | | | +-- -R-- EnumVal measurementsOutletGroupSensorIsAvailable(2) | | Textual Convention: TruthValue | | Values: true(1), false(2) | +-- -R-- EnumVal measurementsOutletGroupSensorState(3) | | Textual Convention: SensorStateEnumeration | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | +-- -R-- Unsigned measurementsOutletGroupSensorValue(4) | +-- -R-- Unsigned measurementsOutletGroupSensorTimeStamp(5) | +-- -R-- Integer32 measurementsOutletGroupSensorSignedValue(6) | +--log(6) | | | +--logUnit(1) | | | | | +--logIndexTable(1) | | | | | | | +--logIndexEntry(1) | | | | Index: pduId | | | | | | | +-- -R-- Integer32 oldestLogID(2) | | | +-- -R-- Integer32 newestLogID(3) | | | | | +--logTimeStampTable(2) | | | | | | | +--logTimeStampEntry(1) | | | | Index: pduId, logIndex | | | | | | | +-- ---- Integer32 logIndex(1) | | | | Range: 1..256 | | | +-- -R-- Unsigned logTimeStamp(2) | | | | | +--unitSensorLogTable(3) | | | | | +--unitSensorLogEntry(1) | | | Index: pduId, sensorType, logIndex | | | | | +-- -R-- EnumVal logUnitSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logUnitSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logUnitSensorAvgValue(4) | | +-- -R-- Unsigned logUnitSensorMaxValue(5) | | +-- -R-- Unsigned logUnitSensorMinValue(6) | | +-- -R-- Integer32 logUnitSensorSignedAvgValue(7) | | +-- -R-- Integer32 logUnitSensorSignedMaxValue(8) | | +-- -R-- Integer32 logUnitSensorSignedMinValue(9) | | | +--logInlet(2) | | | | | +--inletSensorLogTable(3) | | | | | | | +--inletSensorLogEntry(1) | | | | Index: pduId, inletId, sensorType, logIndex | | | | | | | +-- -R-- EnumVal logInletSensorDataAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal logInletSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned logInletSensorAvgValue(4) | | | +-- -R-- Unsigned logInletSensorMaxValue(5) | | | +-- -R-- Unsigned logInletSensorMinValue(6) | | | +-- -R-- Integer32 logInletSensorSignedAvgValue(7) | | | +-- -R-- Integer32 logInletSensorSignedMaxValue(8) | | | +-- -R-- Integer32 logInletSensorSignedMinValue(9) | | | | | +--inletPoleSensorLogTable(4) | | | | | +--inletPoleSensorLogEntry(1) | | | Index: pduId, inletId, inletPoleIndex, sensorType, logIndex | | | | | +-- -R-- EnumVal logInletPoleSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logInletPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logInletPoleSensorAvgValue(4) | | +-- -R-- Unsigned logInletPoleSensorMaxValue(5) | | +-- -R-- Unsigned logInletPoleSensorMinValue(6) | | +-- -R-- Integer32 logInletPoleSensorSignedAvgValue(7) | | +-- -R-- Integer32 logInletPoleSensorSignedMaxValue(8) | | +-- -R-- Integer32 logInletPoleSensorSignedMinValue(9) | | | +--logOverCurrentProtector(3) | | | | | +--overCurrentProtectorSensorLogTable(3) | | | | | +--overCurrentProtectorSensorLogEntry(1) | | | Index: pduId, overCurrentProtectorIndex, sensorType, logIndex | | | | | +-- -R-- EnumVal logOverCurrentProtectorSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logOverCurrentProtectorSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logOverCurrentProtectorSensorAvgValue(4) | | +-- -R-- Unsigned logOverCurrentProtectorSensorMaxValue(5) | | +-- -R-- Unsigned logOverCurrentProtectorSensorMinValue(6) | | +-- -R-- Integer32 logOverCurrentProtectorSensorSignedAvgValue(7) | | +-- -R-- Integer32 logOverCurrentProtectorSensorSignedMaxValue(8) | | +-- -R-- Integer32 logOverCurrentProtectorSensorSignedMinValue(9) | | | +--logOutlet(4) | | | | | +--outletSensorLogTable(3) | | | | | | | +--outletSensorLogEntry(1) | | | | Index: pduId, outletId, sensorType, logIndex | | | | | | | +-- -R-- EnumVal logOutletSensorDataAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal logOutletSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned logOutletSensorAvgValue(4) | | | +-- -R-- Unsigned logOutletSensorMaxValue(5) | | | +-- -R-- Unsigned logOutletSensorMinValue(6) | | | +-- -R-- Integer32 logOutletSensorSignedAvgValue(7) | | | +-- -R-- Integer32 logOutletSensorSignedMaxValue(8) | | | +-- -R-- Integer32 logOutletSensorSignedMinValue(9) | | | | | +--outletPoleSensorLogTable(4) | | | | | +--outletPoleSensorLogEntry(1) | | | Index: pduId, outletId, outletPoleIndex, sensorType, logIndex | | | | | +-- -R-- EnumVal logOutletPoleSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logOutletPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logOutletPoleSensorAvgValue(4) | | +-- -R-- Unsigned logOutletPoleSensorMaxValue(5) | | +-- -R-- Unsigned logOutletPoleSensorMinValue(6) | | +-- -R-- Integer32 logOutletPoleSensorSignedAvgValue(7) | | +-- -R-- Integer32 logOutletPoleSensorSignedMaxValue(8) | | +-- -R-- Integer32 logOutletPoleSensorSignedMinValue(9) | | | +--logExternalSensor(5) | | | | | +--externalSensorLogTable(3) | | | | | +--externalSensorLogEntry(1) | | | Index: pduId, sensorID, logIndex | | | | | +-- -R-- EnumVal logExternalSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logExternalSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Integer32 logExternalSensorAvgValue(4) | | +-- -R-- Integer32 logExternalSensorMaxValue(5) | | +-- -R-- Integer32 logExternalSensorMinValue(6) | | | +--logWire(6) | | | | | +--wireSensorLogTable(3) | | | | | +--wireSensorLogEntry(1) | | | Index: pduId, wireId, sensorType, logIndex | | | | | +-- -R-- EnumVal logWireSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logWireSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logWireSensorAvgValue(4) | | +-- -R-- Unsigned logWireSensorMaxValue(5) | | +-- -R-- Unsigned logWireSensorMinValue(6) | | | +--logTransferSwitch(7) | | | | | +--transferSwitchSensorLogTable(3) | | | | | +--transferSwitchSensorLogEntry(1) | | | Index: pduId, transferSwitchId, sensorType, logIndex | | | | | +-- -R-- EnumVal logTransferSwitchSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logTransferSwitchSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logTransferSwitchSensorAvgValue(4) | | +-- -R-- Unsigned logTransferSwitchSensorMaxValue(5) | | +-- -R-- Unsigned logTransferSwitchSensorMinValue(6) | | +-- -R-- Integer32 logTransferSwitchSensorSignedAvgValue(7) | | +-- -R-- Integer32 logTransferSwitchSensorSignedMaxValue(8) | | +-- -R-- Integer32 logTransferSwitchSensorSignedMinValue(9) | | | +--logCircuit(8) | | | | | +--circuitSensorLogTable(3) | | | | | | | +--circuitSensorLogEntry(1) | | | | Index: pduId, circuitId, sensorType, logIndex | | | | | | | +-- -R-- EnumVal logCircuitSensorDataAvailable(2) | | | | Textual Convention: TruthValue | | | | Values: true(1), false(2) | | | +-- -R-- EnumVal logCircuitSensorState(3) | | | | Textual Convention: SensorStateEnumeration | | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | | +-- -R-- Unsigned logCircuitSensorAvgValue(4) | | | +-- -R-- Unsigned logCircuitSensorMaxValue(5) | | | +-- -R-- Unsigned logCircuitSensorMinValue(6) | | | +-- -R-- Integer32 logCircuitSensorSignedAvgValue(7) | | | +-- -R-- Integer32 logCircuitSensorSignedMaxValue(8) | | | +-- -R-- Integer32 logCircuitSensorSignedMinValue(9) | | | | | +--circuitPoleSensorLogTable(5) | | | | | +--circuitPoleSensorLogEntry(1) | | | Index: pduId, circuitId, circuitPoleId, sensorType, logIndex | | | | | +-- -R-- EnumVal logCircuitPoleSensorDataAvailable(2) | | | Textual Convention: TruthValue | | | Values: true(1), false(2) | | +-- -R-- EnumVal logCircuitPoleSensorState(3) | | | Textual Convention: SensorStateEnumeration | | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | | +-- -R-- Unsigned logCircuitPoleSensorAvgValue(4) | | +-- -R-- Unsigned logCircuitPoleSensorMaxValue(5) | | +-- -R-- Unsigned logCircuitPoleSensorMinValue(6) | | +-- -R-- Integer32 logCircuitPoleSensorSignedAvgValue(7) | | +-- -R-- Integer32 logCircuitPoleSensorSignedMaxValue(8) | | +-- -R-- Integer32 logCircuitPoleSensorSignedMinValue(9) | | | +--logOutletGroup(9) | | | +--outletGroupSensorLogTable(3) | | | +--outletGroupSensorLogEntry(1) | | Index: outletGroupId, sensorType, logIndex | | | +-- -R-- EnumVal logOutletGroupSensorDataAvailable(2) | | Textual Convention: TruthValue | | Values: true(1), false(2) | +-- -R-- EnumVal logOutletGroupSensorState(3) | | Textual Convention: SensorStateEnumeration | | Values: unavailable(-1), open(0), closed(1), belowLowerCritical(2), belowLowerWarning(3), normal(4), aboveUpperWarning(5), aboveUpperCritical(6), on(7), off(8), detected(9), notDetected(10), alarmed(11), ok(12), fail(14), yes(15), no(16), standby(17), one(18), two(19), inSync(20), outOfSync(21), i1OpenFault(22), i1ShortFault(23), i2OpenFault(24), i2ShortFault(25), fault(26), warning(27), critical(28), selfTest(29), nonRedundant(30) | +-- -R-- Unsigned logOutletGroupSensorAvgValue(4) | +-- -R-- Unsigned logOutletGroupSensorMaxValue(5) | +-- -R-- Unsigned logOutletGroupSensorMinValue(6) | +-- -R-- Integer32 logOutletGroupSensorSignedAvgValue(7) | +-- -R-- Integer32 logOutletGroupSensorSignedMaxValue(8) | +-- -R-- Integer32 logOutletGroupSensorSignedMinValue(9) | +--conformance(9) | | | +--compliances(1) | | | | | +--complianceRev1(1) | | +--complianceRev2(2) | | | +--groups(2) | | | +--configGroup(1) | +--logGroup(2) | +--measurementsGroup(3) | +--controlGroup(4) | +--trapInformationGroup(5) | +--trapsGroup(9) | +--reliabilityGroup(10) | +--ipAddressGroup(12) | +--oldConfigGroup(13) | +--oldTrapsGroup(16) | +--obsoleteTrapsGroup(17) | +--obsoleteObjectsGroup(20) | +--reliability(10) | +--reliabilityData(1) | | | +-- -R-- Integer32 reliabilityDataTableSequenceNumber(1) | | Range: 1..2147483647 | | | +--reliabilityDataTable(2) | | | +--reliabilityDataEntry(1) | | Index: reliabilityIndex | | | +-- ---- Integer32 reliabilityIndex(1) | | Range: 1..4096 | +-- -R-- String reliabilityId(2) | | Textual Convention: DisplayString | | Size: 0..255 | +-- -R-- Unsigned reliabilityDataValue(3) | +-- -R-- Unsigned reliabilityDataMaxPossible(4) | +-- -R-- Unsigned reliabilityDataWorstValue(5) | +-- -R-- Unsigned reliabilityDataThreshold(6) | +-- -R-- Unsigned reliabilityDataRawUpperBytes(7) | +-- -R-- Unsigned reliabilityDataRawLowerBytes(8) | +-- -R-- BitString reliabilityDataFlags(9) | Values: invalidFlag(0), oldValue(1), criticalEntry(2) | +--reliabilityErrorLog(2) | | | +--reliabilityErrorLogTable(2) | | | +--reliabilityErrorLogEntry(1) | | Index: reliabilityErrorLogIndex | | | +-- ---- Integer32 reliabilityErrorLogIndex(1) | | Range: 1..2147483647 | +-- -R-- String reliabilityErrorLogId(2) | | Textual Convention: DisplayString | | Size: 0..255 | +-- -R-- Unsigned reliabilityErrorLogValue(3) | +-- -R-- Unsigned reliabilityErrorLogThreshold(6) | +-- -R-- Unsigned reliabilityErrorLogRawUpperBytes(7) | +-- -R-- Unsigned reliabilityErrorLogRawLowerBytes(8) | +-- -R-- Unsigned reliabilityErrorLogPOH(9) | +-- -R-- Unsigned reliabilityErrorLogTime(10) | +--reliabilityHardwareHealth(3) | +--hwFailureTable(1) | +--hwFailureEntry(1) | Index: pduId, hwFailureIndex | +-- ---- Integer32 hwFailureIndex(1) | Range: 1..65535 +-- -R-- String hwFailureComponentId(2) | Textual Convention: DisplayString | Size: 0..255 +-- -R-- EnumVal hwFailureType(3) | Textual Convention: HwFailureTypeEnumeration | Values: networkDeviceNotDetected(1), i2cBusStuck(2), slaveCtrlNotReachable(3), slaveCtrlMalfunction(4), outletPowerStateInconsistent(5) +-- -R-- EnumVal hwFailureAsserted(4) | Textual Convention: TruthValue | Values: true(1), false(2) +-- -R-- Unsigned hwFailureLastAssertTimeStamp(5) +-- -R-- Unsigned hwFailureLastDeassertTimeStamp(6) +-- -R-- Unsigned hwFailureAssertCount(7)